BP122841 - 2256 Ashlee Road
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search Again| BP122841 - 2256 Ashlee Road | |
|---|---|
| Neighbourhood: | Westwood | 
| Street Address: | 2256 Ashlee Road | 
| Type of Application: | Accessory Building | 
| File Number: | BP122841 | 
| Date Application Submitted: | January 23, 2017 | 
| Application Description: | New Carriage House and Garage REVISION: Dec 11 2017 - 2 Strip Footings deleted REVISION: Dec 11 2017 - Geotech P. Eng. added Feb 2/18: Revision - add entry foyer and covered entry REVISION: Feb 28 2018 - layout change in garage | 
| Application Status: | COMPLETED | 
| Permit Value: | $140,000.00 | 
| Building Area: | 60.11 M2 647.02 ft2 | 
| Builder: | 0761349 BC LTD DBA HOMETEC | 
| Issued Date: | December 06, 2017 | 
| File Close Date: | August 30, 2018 | 
| Expiry Date: | December 06, 2019 | 
Process Steps
| Task | Status | 
|---|---|
| EXCAVATION Excavation of soil, prior to placing forms. | FAILED | 
| FOOTING/FORMS Inspection of Forms prior to any concrete being poured for footing inspection. Forms must be complete and approved plans (complete with City Stamp) must be onsite. | FAILED | 
| FOOTING/FORMS Inspection of Forms prior to any concrete being poured for footing inspection. Forms must be complete and approved plans (complete with City Stamp) must be onsite. | PARTIAL | 
| FOOTING/FORMS Inspection of Forms prior to any concrete being poured for footing inspection. Forms must be complete and approved plans (complete with City Stamp) must be onsite. | PASSED | 
| PERIMETER DRAIN For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering. | PASSED | 
| WATER CONNECTION Pipe and connection must be visible for inspection. | PASSED | 
| SANITARY CONNECTION Pipe and Connection must be visible for inspection. | PASSED | 
| STORM CONNECTION Pipe and Connection must be visible for inspection | PASSED | 
| UNDERSLAB PLUMBING Complete underslab plumbing must be visible. | PASSED | 
| UNDERSLAB INSULATION Inspection required prior to placing slab concrete. | FAILED | 
| UNDERSLAB INSULATION Inspection required prior to placing slab concrete. | PASSED | 
| UNDERSLAB INSULATION Inspection required prior to placing slab concrete. | PASSED | 
| ROUGH IN PLUMBING Rough in plumbing must be complete including potable water piping. | PASSED | 
| LATERAL BRACING & SHEATHING All nailing and blocking associated with braced wall panels to be completed for this inspection. Wood-based interior braced wall panels to be sheathed. Exterior braced wall panel locations to be clearly marked out on the interior and exterior. Interior braced wall panels to be clearly marked so their location can be seen now and later at the time of INTERIOR BRACED WALL PANEL INSPECTION. Additional anchor bolts shall be installed two per braced wall panel where a building contains framed walls supporting more than two floors. | CANCELLED | 
| LATERAL BRACING & SHEATHING All nailing and blocking associated with braced wall panels to be completed for this inspection. Wood-based interior braced wall panels to be sheathed. Exterior braced wall panel locations to be clearly marked out on the interior and exterior. Interior braced wall panels to be clearly marked so their location can be seen now and later at the time of INTERIOR BRACED WALL PANEL INSPECTION. Additional anchor bolts shall be installed two per braced wall panel where a building contains framed walls supporting more than two floors. | PARTIAL | 
| LATERAL BRACING & SHEATHING All nailing and blocking associated with braced wall panels to be completed for this inspection. Wood-based interior braced wall panels to be sheathed. Exterior braced wall panel locations to be clearly marked out on the interior and exterior. Interior braced wall panels to be clearly marked so their location can be seen now and later at the time of INTERIOR BRACED WALL PANEL INSPECTION. Additional anchor bolts shall be installed two per braced wall panel where a building contains framed walls supporting more than two floors. | PASSED | 
| PAPER/FLASHING/WATERPROOFING When framing, sheathing, building paper, flashing, weatherproofing of openings and window installation is complete, but before installation of any siding, wire mesh or stucco. | PARTIAL | 
| PAPER/FLASHING/WATERPROOFING When framing, sheathing, building paper, flashing, weatherproofing of openings and window installation is complete, but before installation of any siding, wire mesh or stucco. | FAILED | 
| FRAMING Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. | FAILED | 
| FRAMING Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. | PASSED | 
| INSULATION Insulation and vapour barrier to be complete prior to inspection. | FAILED | 
| INSULATION Insulation and vapour barrier to be complete prior to inspection. | PASSED | 
| INTERIOR BRACED WALL PANELS | CANCELLED | 
| INTERIOR BRACED WALL PANELS | PASSED | 
| OCCUPANCY-OLD Occupancy inspection to be used for new accessory suite (Carriage House). Covenant must be registered on title, HPO in place, private outdoor space must be provided for occupants, one onsite parking spot | FAILED | 
| OCCUPANCY-OLD Occupancy inspection to be used for new accessory suite (Carriage House). Covenant must be registered on title, HPO in place, private outdoor space must be provided for occupants, one onsite parking spot | PASSED 2018-08-30 | 
| Map | 
|---|
|  View in Google Earth (KML) | 
            
            Disclaimer:
            
            The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
            Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
            The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
            
            The Information Provided within this website is for Informational Purposes Only.
            It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.
            
        