BP120731 - 633 Victoria Road
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search AgainBP120731 - 633 Victoria Road | |
---|---|
Neighbourhood: | South End |
Street Address: | 633 Victoria Road |
Type of Application: | Single / Two Family Alteration |
File Number: | BP120731 |
Date Application Submitted: | April 01, 2015 |
Application Description: |
12' x 18' master ensuite, laundry and mud room addition plus 10' x 16' deck addition with stairs 2015-JUN-08 REVISION reduced deck size to landing size, added structural engineered ftg/fdn for landing/steps, by complete with Schedule B. Geotechnical report and Schedule B submitted for underlying coalmine works.See details in Conditions...MLB REVISION#2 Increase landing size to deck size, now 5' by9'-6". Add roof assembly over the original landing footprint. |
Application Status: | COMPLETED |
Permit Value: | $55,000.00 |
Building Area: |
20.07 M2 216.03 ft2 |
Builder: | B GALLANT HOMES LTD |
Issued Date: | May 01, 2015 |
File Close Date: | January 19, 2016 |
Expiry Date: | May 01, 2017 |
Associated Properties
Address | Zone | More |
---|---|---|
633 VICTORIA ROAD | R5 | Property Report |
Process Steps
Task | Status |
---|---|
FOOTING/FORMS
Inspection of forms prior to any concrete being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite. |
PARTIAL |
FOOTING/FORMS
Inspection of forms prior to any concrete being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite. |
PASSED |
PERIMETER DRAIN
For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering. |
PARTIAL |
PERIMETER DRAIN
For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering. |
PASSED |
UNDERSLAB INSULATION
Inspection required prior to placing slab concrete. |
PASSED |
ROUGH IN PLUMBING
Rough In plumbing must be complete including water piping. |
PARTIAL |
PAPER/FLASHING/WATERPROOFING
When framing, sheathing, building paper, flashing, weatherproofing of openings and window installation is complete, but before installation of any siding, wire mesh or stucco. |
PARTIAL |
PAPER/FLASHING/WATERPROOFING
When framing, sheathing, building paper, flashing, weatherproofing of openings and window installation is complete, but before installation of any siding, wire mesh or stucco. |
PASSED |
LATERAL BRACING & SHEATHING
All nailing and blocking associated with braced wall panels to be completed for this inspection. Wood-based interior braced wall panels to be sheathed. Exterior braced wall panel locations to be clearly marked out on the interior and exterior. Interior braced wall panels to be clearly marked so their location can be seen now and later at the time of INTERIOR BRACED WALL PANEL INSPECTION. Additional anchor bolts shall be installed two per braced wall panel where a building contains framed walls supporting more than two floors. |
PASSED |
FRAMING
Rough in plumbing & electrical must be complete. |
PARTIAL |
FRAMING
Rough in plumbing & electrical must be complete. |
PASSED |
INSULATION
Insulation and vapour barrier to be complete prior to inspection |
PARTIAL |
INSULATION
Insulation and vapour barrier to be complete prior to inspection |
PASSED |
FINAL-OLD
Final approval as per requirements on plans. |
FAILED |
FINAL-OLD
Final approval as per requirements on plans. |
PASSED
2016-01-19 |
Map |
---|
![]() |
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.