BP120690 - 2205 Northfield Road

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP120690 - 2205 Northfield Road
Neighbourhood: Northfield    
Street Address: 2205 Northfield Road
Type of Application: Commercial / Multi / Industrial
File Number: BP120690
Date Application Submitted: March 20, 2015
Application Description: Addition to existing building. Part 9, 2 stories, sprinklered , no fire alarm,
Lower floor, First storey, Group E, installing , 1 Universal washroom . 1 hour fire separation/fire resistance plus 50 STM between Group C and Group E between upper and lower floors and egress stairs from upper floor, 45 min between Group E to Group E , 1 hour FRR with non combustible cladding on south and west.
Upper floor , second storey , Group C, one dwelling unit, 1 hour fire separation/fire resistance plus 50 STM between Group C and Group E and 45 min/50 STM between Group C to Group C, Exterior, West 1 hour FRR with non combustible cladding, Exterior, South 1 hour FRR with non combustible cladding provided , combustible permitted.

Existing first storey = 329.5 sq. m + adding 100.5 sq. m.. New total floor area of first storey (Group E) = 430.0 sq. m.
Existing second 106 m2 + addition of 81 sq. m. Now total floor area of second floor (Group C) - 187 sq. m .


Application Status: COMPLETED
Permit Value: $300,000.00
Builder: AHAUS CONSTRUCTION LTD
Issued Date: April 20, 2015
File Close Date: September 25, 2015
Expiry Date: April 20, 2017

Associated Properties

Address Zone More
2205 NORTHFIELD ROAD COR3 Property Report

Process Steps

Task Status
FOOTING/FORMS

Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite.

PARTIAL
PERIMETER DRAIN

For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering.

PASSED
UNDERSLAB PLUMBING

complete underslab plumbing must be visible.

PASSED
UNDERSLAB INSULATION

Inspection required prior to placing slab concrete.

PASSED
SANITARY CONNECTION

Pipe and connection must be visible for inspection.

PASSED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PARTIAL
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PASSED
PAPER/FLASHING/WATERPROOFING

When framing, sheathing, building paper, flashing, weatherproofing of openings and window installation is complete, but before installation of any siding, wire mesh or stucco.

PARTIAL
PAPER/FLASHING/WATERPROOFING

When framing, sheathing, building paper, flashing, weatherproofing of openings and window installation is complete, but before installation of any siding, wire mesh or stucco.

PASSED
PAPER/FLASHING/WATERPROOFING

When framing, sheathing, building paper, flashing, weatherproofing of openings and window installation is complete, but before installation of any siding, wire mesh or stucco.

PARTIAL
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visable for inspection.

PARTIAL
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PARTIAL
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PASSED
FINAL-OLD

Final approval as per requirements on plans.

FAILED
FINAL-OLD

Final approval as per requirements on plans.

PASSED

2015-09-25

Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.

The Information Provided within this website is for Informational Purposes Only. It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

Help us improve our website

Don't include private or financial information in this form.

Collection and use of your personal information
Information collected on this form is done so under the general authority of the Community Charter and Freedom of Information and Protection of Privacy Act (FOIPPA), and is protected in accordance with FOIPPA.  Personal information will only be used by authorized staff to fulfill the purpose for which it was originally collected, or for a use consistent with that purpose. Questions about the collection of your personal information may be referred to the Legislative Services Department at (250) 755-4405, or via email at foi@nanaimo.ca.
Privacy Policy