BP120497 - 2052 Boxwood Road
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search AgainBP120497 - 2052 Boxwood Road | |
---|---|
Neighbourhood: | Northfield |
Street Address: | 2052 Boxwood Road |
Type of Application: | Commercial / Multi-Res Alteration |
File Number: | BP120497 |
Date Application Submitted: | December 18, 2014 |
Application Description: |
Conversion of 2nd storey to dwelling unit. 196.6 m2. Group C , private exit stairway for dwelling unit, adding new exit door on the main floor. Wall assembly: 2 hr FRR/FS -50 STC between F2/ C, Floor Assembly : 1 Hr FRR/FS - 50 STC between C/E and exit separation; Previous RI for plumbing , final plumbing under this permit and 4 new sprinkler heads added. Existing building : Part 3 Building , 2 Storeys, Sprinklered, Fire Alarm System, 1st storey, Industrial (Group F2) occupancies and Retail sales and display , 2nd Storey, Industrial (Group F2) Storage. 1st Storey = 872.8 m2, 2nd Storey = 179.6 m2, Construction Article 3.2.2.77, 45 min. FRR/FS for floor assembly and 45 min. for load-bearing supports if combustible and 45 min. FRR/FS for 2nd storey wall separation and 45 min. for the exit enclosure. |
Application Status: | COMPLETED |
Permit Value: | $40,000.00 |
Building Area: |
196.60 M2 2,116.18 ft2 |
Builder: | 506675 BC LTD |
Issued Date: | January 21, 2015 |
File Close Date: | December 11, 2015 |
Expiry Date: | January 21, 2017 |
Process Steps
Task | Status |
---|---|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PARTIAL |
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PARTIAL |
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PASSED |
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
PASSED |
PLUMBING FINAL-OLD
All fixtures must be in place. |
PARTIAL |
PLUMBING FINAL-OLD
All fixtures must be in place. |
FAILED |
PLUMBING FINAL-OLD
All fixtures must be in place. |
PASSED |
FINAL-OLD
Final approval as per requirements on plans. |
FAILED |
FINAL-OLD
Final approval as per requirements on plans. |
PASSED
2015-12-11 |
Map |
---|
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.