BP120208 - 303 - 1621 Dufferin Crescent
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search AgainBP120208 - 303 - 1621 Dufferin Crescent | |
---|---|
Neighbourhood: | Northfield |
Street Address: | 303 - 1621 Dufferin Crescent |
Type of Application: | Leasehold Improvements |
File Number: | BP120208 |
Date Application Submitted: | September 30, 2014 |
Application Description: |
Medical Office - Unit 303- complete and occupy - 105.6 m2 - 2 exam rooms with sinks , 2 offices , 1 staff area with sink , 1 reception desk and waiting room , 1 accessible washroom, O hr. FS/FRR between suites, 0 hr. FS/FRR public corridors, 45 min. FRR/FS for exits at each end of public corridor. Building designed to 3.2.2.65 Group E, 3.2.2.24, Group A2 and 3.2.2.59 Group D superimposed major occupancies. 3 storey, non-combustible construction, sprinklers and fire alarm. 1 hour FRR/FS floor assembly required above the first storey including supporting construction. O Hr. FRR/FS required above the second storey and roof. 1.5 hrs FRR/FS to parking garage. 2763 m2 total on 3 floors, with 1353m2 parking garage(BCBC building area =2274 m2) |
Application Status: | COMPLETED |
Permit Value: | $80,000.00 |
Building Area: |
105.60 M2 1,136.67 ft2 |
Builder: | RW (BOB) WALL LTD |
Issued Date: | October 30, 2014 |
File Close Date: | January 08, 2015 |
Expiry Date: | October 31, 2016 |
Associated Properties
Address | Zone | More |
---|---|---|
303 1621 DUFFERIN CRESCENT | CC5 | Property Report |
1621 DUFFERIN CRESCENT | CC5 | Property Report |
Process Steps
Task | Status |
---|---|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PASSED |
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval. |
PARTIAL |
PLUMBING FINAL-OLD
All fixtures must be in place. |
PARTIAL |
PLUMBING FINAL-OLD
All fixtures must be in place. |
PASSED |
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
PARTIAL |
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
PASSED |
FINAL-OLD
Final Approval as per requirements on plans. |
FAILED |
FINAL-OLD
Final Approval as per requirements on plans. |
PASSED
2015-01-08 |
Map |
---|
![]() |
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.