BP119854 - 1483 Bowen Road
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search AgainBP119854 - 1483 Bowen Road | |
---|---|
Neighbourhood: | Northfield |
Street Address: | 1483 Bowen Road |
Type of Application: | Leasehold Improvements |
File Number: | BP119854 |
Date Application Submitted: | June 12, 2014 |
Application Description: |
Wa-Ku Restaurant, 110.3 m2 , " Group A2 " Occupancy - New Restaurant - 29 seat restaurant (limited by parking.) Occupant load = 33 persons includes staff. Existing 2 hour FRR/FS block wall between this unit and adjacent unit Group E (Take out) , repair any breaches in the existing 2 hour and 1 hour demising wall. Existing one hour wall between this unit and adjacent Group D. Adding two new accessible (universal) washrooms, New NFPA 96 kitchen exhaust hood. New sinks. Two exits required. 3.2.2.28 for A2 purposes only, single storey combustible 334.44 m2 building, unsprinklered block construction with existing block wall dividing one third of the building. |
Application Status: | COMPLETED |
Permit Value: | $50,000.00 |
Building Area: |
110.37 M2 1,188.01 ft2 |
Builder: | KTM3 ENTERPRISE LTD |
Issued Date: | July 11, 2014 |
File Close Date: | August 29, 2014 |
Expiry Date: | July 11, 2016 |
Associated Properties
Address | Zone | More |
---|---|---|
1483 BOWEN ROAD | COR3 | Property Report |
Process Steps
Task | Status |
---|---|
UNDERSLAB PLUMBING
Complete underslab plumbing must be visible. |
PASSED |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
FAILED |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval. |
FAILED |
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval. |
CANCELLED |
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval. |
PARTIAL |
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval. |
PASSED |
PLUMBING FINAL-OLD
All fixtures must be in place. |
CANCELLED |
PLUMBING FINAL-OLD
All fixtures must be in place. |
PARTIAL |
PLUMBING FINAL-OLD
All fixtures must be in place. |
PASSED |
FINAL-OLD
Final Approval as per requirements on plans. |
CANCELLED |
FINAL-OLD
Final Approval as per requirements on plans. |
FAILED |
FINAL-OLD
Final Approval as per requirements on plans. |
PASSED
2014-08-29 |
Map |
---|
![]() |
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.