BP119271 - 201 648 Terminal(Timbewest)
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search AgainBP119271 - 201 648 Terminal(Timbewest) | |
---|---|
Neighbourhood: | Downtown/Old City |
Street Address: | 201 648 Terminal(Timbewest) |
Type of Application: | Leasehold Improvements |
File Number: | BP119271 |
Date Application Submitted: | December 20, 2013 |
Application Description: |
Complete and Occupy for Offices (TimberWest) - Group D, Accessible floor area = 1657 m2 , installing new interior finishes to create office; including, partition walls, T-bar and gypsum ceiling. Installing 2 hr FRR/FS demising wall between this suite and the adjacent suite and 2 hr exit/egress corridor at top of existing exit enclosure . Installing 1 new unisex washroom, 1 sink in coffee room, 1 sink in boardroom and 1 sink in staff room. Existing universal , female and male washrooms ( no change). Building D - Two Storey Building, 2,351.8 m2 on first and 2,221.8 m2 on second floor. Building classification, Most restricticve: Group A2 : 3.2.2,23 and Group E 3.2.2.65. , Non-combustible construction, Sprinklered, Fire alarm system , 2 hr FRR/FS for Exits and Floor Assemblies . Alternative Solution for openings in fire separation, exit exposure and exit lobby design,x reference BP117610. Relocated entry door 2014/02/21 |
Application Status: | COMPLETED |
Permit Value: | $750,000.00 |
Building Area: |
1,657.00 M2 17,835.78 ft2 |
Builder: | ISLAND WEST COAST DEVELOPMENTS |
Issued Date: | January 29, 2014 |
File Close Date: | April 24, 2014 |
Expiry Date: | January 29, 2016 |
Associated Properties
Address | Zone | More |
---|---|---|
650 TERMINAL AVENUE | DT6 , DT6 | Property Report |
Process Steps
Task | Status |
---|---|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval. |
PARTIAL |
PLUMBING FINAL-OLD
All fixtures must be in place. |
PARTIAL |
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
PARTIAL |
FINAL-OLD
Final Approval as per requirements on plans. |
FAILED |
FINAL-OLD
Final Approval as per requirements on plans. |
FAILED |
FINAL-OLD
Final Approval as per requirements on plans. |
PASSED
2014-04-24 |
Map |
---|
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.