BP118639 - 1451 Estevan Road

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP118639 - 1451 Estevan Road
Neighbourhood: Newcastle/Brechin    
Street Address: 1451 Estevan Road
Type of Application: Commercial / Multi / Industrial
File Number: BP118639
Date Application Submitted: May 27, 2013
Application Description: New 3 storey office building for VIHA Shell building and Related site works. Building Description, Part 3, Governing article 3.2.2.2.59 BCBC 2012. Combustible or non combustible construction permitted non combustible provided. Floor assemblies FS with 0Hr FRR, 1hr Provided. Loadbearing walls comlumns and arches required to be non combustible no rating required 1hr provided. Vertical service spaces FS no FRR required . Elevator hoistway to be a FSwith a 45min FRR. Elevator service room FS with 45min FRR. Service rooms consturcted as FS with 1Hr FRR. South exposed building face with 6.3m L.D.(for future building) Requires 45min FRR. East exposed building face requires Non combustible construction and non combustible cladding and 1Hr FRR. Building sprinkled with fire alarm. Building Area by code 380.37m2. First storey group D floor area 331.59m2. Second storey group D 333.45m2. Third storey group D 333.45m3
Application Status: COMPLETED
Permit Value: $1,200,000.00
Issued Date: October 04, 2013
File Close Date: October 31, 2014
Expiry Date: October 04, 2015

Associated Properties

Address Zone More
1451 ESTEVAN ROAD CC3 Property Report

Process Steps

Task Status
PERIMETER DRAIN

For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering.

SCHEDULED
UNDERSLAB PLUMBING

complete underslab plumbing must be visible.

PARTIAL
UNDERSLAB PLUMBING

complete underslab plumbing must be visible.

PARTIAL
UNDERSLAB INSULATION

Inspection required prior to placing slab concrete.

PASSED
STORM CONNECTION

Pipe and connection must be visible for inspection.

CANCELLED
SANITARY CONNECTION

Pipe and connection must be visible for inspection.

CANCELLED
WATER CONNECTION

Pipe and connection must be visible for inspection.

PARTIAL
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PARTIAL
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PARTIAL
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PARTIAL
OCCUPANCY-OLD PASSED

2014-10-31

FINAL-OLD

Final approval as per requirements on plans.

CANCELLED
Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.

The Information Provided within this website is for Informational Purposes Only. It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

Help us improve our website

Don't include private or financial information in this form.

Collection and use of your personal information
Information collected on this form is done so under the general authority of the Community Charter and Freedom of Information and Protection of Privacy Act (FOIPPA), and is protected in accordance with FOIPPA.  Personal information will only be used by authorized staff to fulfill the purpose for which it was originally collected, or for a use consistent with that purpose. Questions about the collection of your personal information may be referred to the Legislative Services Department at (250) 755-4405, or via email at foi@nanaimo.ca.
Privacy Policy