BP118062 - Unit 1 - 4515 Uplands -- Scanned
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search AgainBP118062 - Unit 1 - 4515 Uplands -- Scanned | |
---|---|
Neighbourhood: | Rutherford |
Street Address: | Unit 1 - 4515 Uplands -- Scanned |
Type of Application: | Leasehold Improvements |
File Number: | BP118062 |
Date Application Submitted: | November 21, 2012 |
Application Description: |
Create 2 CRU's from unit 1 space, new addresses will be 1A & 1B. 2 hour demising wall to divide space. Tenant improvement to Unit 1B - Barry A Lewis Denture Clinic 160.6 m2 & future CRU 46.2 m2. Max. travel distance for single exit is 25 m. T.I. includes partion walls, adding 5 sinks and changes to sprinklers. Future permit will be required for Tenant Improvement for CRU 1B. New CRU includes adding HW, rough-in for U/B group. BCBC1998 387.4 sq m, 2 storey, "D" / "A-2", 3.2.2.56. / 3.2.2.27. Part 4 building on full basement, combustible construction, sprinklered with fire alarm system. 387.4 m2 main floor office, 279.7m2 second floor office, 134.5m2 basement storage area. 3/4 hr fire separation between floors and between "exit" stairwell and suites. Roof to have 3/4 hr rating to separate stairwell from adjoining suites. No fire separation required between office suites. |
Application Status: | COMPLETED |
Permit Value: | $20,000.00 |
Builder: | DUECK GENERAL CONTRACTING |
Issued Date: | December 11, 2012 |
File Close Date: | February 08, 2013 |
Expiry Date: | December 11, 2014 |
Associated Properties
Address | Zone | More |
---|---|---|
4515 UPLANDS DRIVE | COR2 | Property Report |
Process Steps
Task | Status |
---|---|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PASSED |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visible for inspection. |
PASSED |
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval. |
PASSED |
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
PARTIAL |
FINAL-OLD
Final Approval as per requirements on plans. |
FAILED |
FINAL-OLD
Final Approval as per requirements on plans. |
FAILED |
FINAL-OLD
Final Approval as per requirements on plans. |
PASSED
2013-02-08 |
Map |
---|
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.