BP117697 - 6 6338 Metral Drive -- Scanned(Brown's Social House)
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search AgainBP117697 - 6 6338 Metral Drive -- Scanned(Brown's Social House) | |
---|---|
Neighbourhood: | Pleasant Valley |
Street Address: | 6 6338 Metral Drive -- Scanned(Brown's Social House) |
Type of Application: | Leasehold Improvements |
File Number: | BP117697 |
Date Application Submitted: | August 16, 2012 |
Application Description: |
Brown's Social House, Tenant Improvement Permit - 273.2 m2, A-2 occupancy Maximum travel distance 45m/147.6 ft. Occupant load: 114 patron area, 13 staff area Washrooms provided: 2m/3f/1universal accessible Revision - Jan 8/13: Revised Structural drawings received for enclosed patio area. mv Revision - Jan 29/13: Revised Sprinkler drawings & hydraulic calculations received. 6338 Metral - Bldg C = Shell Bldg only - 2 & 1 hr FRR/FS demising walls for 6 CRU's, Bldg area = 1019 m2, Group A2 & Group E, One storey, 3.2.2.27, Sprinklered, combustible const. OK, Accessible, Fire alarm. |
Application Status: | COMPLETED |
Permit Value: | $592,000.00 |
Building Area: |
272.30 M2 2,931.01 ft2 |
Issued Date: | November 05, 2012 |
File Close Date: | March 19, 2013 |
Expiry Date: | November 05, 2014 |
Associated Properties
Address | Zone | More |
---|---|---|
6334 METRAL DRIVE | CC4 | Property Report |
Process Steps
Task | Status |
---|---|
FOOTING/FORMS
Inspection of Forms prior to any cement being poured for footing inspection, forms must be complete and approved plans (complete with City Stamp) must be onsite. |
PASSED |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visible for inspection. |
PARTIAL |
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval. |
PARTIAL |
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PARTIAL |
PLUMBING FINAL-OLD
All fixtures must be in place. |
PARTIAL |
FINAL-OLD
Final Approval as per requirements on plans. |
CANCELLED |
FINAL-OLD
Final Approval as per requirements on plans. |
FAILED |
FINAL-OLD
Final Approval as per requirements on plans. |
PASSED
2013-03-20 |
Map |
---|
![]() |
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.