BP117577 - Building A - 6543 Portsmouth Road
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search AgainBP117577 - Building A - 6543 Portsmouth Road | |
---|---|
Neighbourhood: | Dover |
Street Address: | Building A - 6543 Portsmouth Road |
Type of Application: | Commercial / Multi / Industrial |
File Number: | BP117577 |
Date Application Submitted: | July 18, 2012 |
Application Description: |
Office Building Building A only Shell building only seperate permit required to complete and occupy. 2 storey, Part 9 Building. Sprinklered. Building Area 501.35m2 Lower floor Area 501.35m2 - 'Group D' Occupancy: Upper floor 372m2 -'Group D' occupancy 45min FS/FRR required for floors, 1hr provided. 45min FRR columns or non combustible required, non combustible provided.(colums are appropriate for support of 45min rated floor BCBC 3.2.2.56) 45min supporting walls required, 1hr provided. 45min FS/FRR required for service shafts 1hr provided. 45min FS/FRR required for roof supporting an occupancy, 1hr provided. EBF of exit stair on east elevation non combustible cladding non combustible construction 1hr FRR Remainder of east EBF 1hr FRR combustible or non combustible cladding and construction. Revision on July 9, 2013 changed phasing for civil work. REVISION ON DEC 6, 2013 RELOCATED WASHROOM TO UNIT 103 AND ADDED WINDOWS TO UNIT 102. jb |
Application Status: | COMPLETED |
Permit Value: | $1,500,000.00 |
Builder: | WESTMARK CONSTRUCTION LTD |
Issued Date: | July 11, 2013 |
File Close Date: | February 26, 2014 |
Associated Properties
Address | Zone | More |
---|---|---|
102 6543 PORTSMOUTH ROAD | CD6 | Property Report |
101 6543 PORTSMOUTH ROAD | CD6 | Property Report |
202 6543 PORTSMOUTH ROAD | CD6 | Property Report |
103 6543 PORTSMOUTH ROAD | CD6 | Property Report |
201 6543 PORTSMOUTH ROAD | CD6 | Property Report |
104 6543 PORTSMOUTH ROAD | CD6 | Property Report |
Process Steps
Task | Status |
---|---|
FOOTING/FORMS
Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite. |
PASSED |
PERIMETER DRAIN
For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering. |
PASSED |
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PARTIAL |
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PARTIAL |
UNDERSLAB INSULATION
Inspection required prior to placing slab concrete. |
PASSED |
PAPER/FLASHING/WATERPROOFING
When framing, sheathing, building paper, flashing, weatherproofing of openings and window installation is complete, but before installation of any siding, wire mesh or stucco. |
PARTIAL |
PAPER/FLASHING/WATERPROOFING
When framing, sheathing, building paper, flashing, weatherproofing of openings and window installation is complete, but before installation of any siding, wire mesh or stucco. |
PASSED |
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PARTIAL |
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PARTIAL |
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PASSED |
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PARTIAL |
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PARTIAL |
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PARTIAL |
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PARTIAL |
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PASSED |
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PASSED |
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PARTIAL |
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
PARTIAL |
PLUMBING FINAL-OLD
All fixtures must be in place. |
PARTIAL |
OCCUPANCY-OLD | FAILED |
OCCUPANCY-OLD | FAILED |
OCCUPANCY-OLD |
PASSED
2014-02-26 |
Map |
---|
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.