BP117375 - 2113 Boxwood Rd - Scanned
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search AgainBP117375 - 2113 Boxwood Rd - Scanned | |
---|---|
Neighbourhood: | Northfield |
Street Address: | 2113 Boxwood Rd - Scanned |
Type of Application: | Commercial / Multi / Industrial |
File Number: | BP117375 |
Date Application Submitted: | May 15, 2012 |
Application Description: | To construct a two storey 49 bed residential building "Edgewood Treatment Centre" - Part 3, Building Classification 3.2.2.48., Group C, Building Area / lower floor area 865.0m2, upper floor area 787.4m2, Gross floor area 1652.4 m2. Sprinklered with Fire Alarm system. Accessible for persons with disabilities to 3.8 / 3.8.2.30. - Dormatories (access required on the lower floor only) Combustible or Non-combustible construction permitted, 45 minute floor assemblies, roof has been rated 45 minutes to permit the fire separations on the upper floor to terminate at the ceiling level, 45 minute supporting construction. Principle Entrance is into an exit enclosure - no occupancy of any type is permitted in the exit enclosure. One universal staff washroom has been provided on the lower floor and one additional staff washroom has been provided on the upper floor. |
Application Status: | HOLDBACK |
Permit Value: | $2,400,000.00 |
Builder: | WINDLEY CONTRACTING (2010) LTD |
Issued Date: | July 31, 2012 |
File Close Date: | January 30, 2013 |
Associated Properties
Address | Zone | More |
---|---|---|
2113 BOXWOOD ROAD | CS1 | Property Report |
Process Steps
Task | Status |
---|---|
FOOTING/FORMS
Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite. |
PARTIAL |
FOOTING/FORMS
Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite. |
PASSED |
PERIMETER DRAIN
For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering. |
PARTIAL |
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PARTIAL |
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PARTIAL |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
PARTIAL |
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PARTIAL |
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PASSED |
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PARTIAL |
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PARTIAL |
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PARTIAL |
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PARTIAL |
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PASSED |
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PARTIAL |
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PASSED |
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
PARTIAL |
OCCUPANCY-OLD | FAILED |
OCCUPANCY-OLD |
PASSED
2013-01-30 |
Map |
---|
![]() |
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.