BP117375 - 2113 Boxwood Rd - Scanned

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP117375 - 2113 Boxwood Rd - Scanned
Neighbourhood: Northfield    
Street Address: 2113 Boxwood Rd - Scanned
Type of Application: Commercial / Multi / Industrial
File Number: BP117375
Date Application Submitted: May 15, 2012
Application Description: To construct a two storey 49 bed residential building "Edgewood Treatment Centre" - Part 3, Building Classification 3.2.2.48., Group C, Building Area / lower floor area 865.0m2, upper floor area 787.4m2, Gross floor area 1652.4 m2. Sprinklered with Fire Alarm system. Accessible for persons with disabilities to 3.8 / 3.8.2.30. - Dormatories (access required on the lower floor only) Combustible or Non-combustible construction permitted, 45 minute floor assemblies, roof has been rated 45 minutes to permit the fire separations on the upper floor to terminate at the ceiling level, 45 minute supporting construction. Principle Entrance is into an exit enclosure - no occupancy of any type is permitted in the exit enclosure. One universal staff washroom has been provided on the lower floor and one additional staff washroom has been provided on the upper floor.
Application Status: HOLDBACK
Permit Value: $2,400,000.00
Builder: WINDLEY CONTRACTING (2010) LTD
Issued Date: July 31, 2012
File Close Date: January 30, 2013

Associated Properties

Address Zone More
2113 BOXWOOD ROAD CS1 Property Report

Process Steps

Task Status
FOOTING/FORMS

Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite.

PARTIAL
FOOTING/FORMS

Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite.

PASSED
PERIMETER DRAIN

For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering.

PARTIAL
UNDERSLAB PLUMBING

complete underslab plumbing must be visible.

PARTIAL
UNDERSLAB PLUMBING

complete underslab plumbing must be visible.

PARTIAL
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PARTIAL
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PARTIAL
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visable for inspection.

PARTIAL
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PARTIAL
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PASSED
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PARTIAL
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PARTIAL
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PARTIAL
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PARTIAL
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PASSED
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PARTIAL
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PASSED
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

PARTIAL
OCCUPANCY-OLD FAILED
OCCUPANCY-OLD PASSED

2013-01-30

Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.

The Information Provided within this website is for Informational Purposes Only. It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

Help us improve our website

Don't include private or financial information in this form.

Collection and use of your personal information
Information collected on this form is done so under the general authority of the Community Charter and Freedom of Information and Protection of Privacy Act (FOIPPA), and is protected in accordance with FOIPPA.  Personal information will only be used by authorized staff to fulfill the purpose for which it was originally collected, or for a use consistent with that purpose. Questions about the collection of your personal information may be referred to the Legislative Services Department at (250) 755-4405, or via email at foi@nanaimo.ca.
Privacy Policy