BP116936 - 6 Maki Road - Addition to Amenities Building -- Scanned

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP116936 - 6 Maki Road - Addition to Amenities Building -- Scanned
Neighbourhood: Chase River    
Street Address: 6 Maki Road - Addition to Amenities Building -- Scanned
Type of Application: Commercial / Multi / Industrial
File Number: BP116936
Date Application Submitted: February 01, 2012
Application Description: Part 9 Building. Addition to existing. Additional floor area added = 84.78m2. . Addition of an office/canteen (D occupancy) with second storey storage area for existing residential dwelling unit use only. Conversion of the existing canteen area to quilting room. A2 with low occupant load classified as Group D per 3.1.2.6 a, b and c. with an Occupant Load of 30. Includes conversion a portion of the existing recreation room to a storage room. Building is an existing Part 9 building Fire separation upgrades are required as shown on the approved plans. 45 minute fire resistance rating on floors, roof assemblies and supporting construction.
Application Status: COMPLETED
Permit Value: $50,000.00
Builder: NANAIMO DELTA PROPERTIES LTD
Issued Date: July 18, 2012
File Close Date: March 27, 2013

Associated Properties

Address Zone More
6 MAKI ROAD AR1 , PRC1 , R11 Property Report

Process Steps

Task Status
FOOTING/FORMS

Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite.

PASSED
PERIMETER DRAIN

For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering.

PASSED
UNDERSLAB PLUMBING

complete underslab plumbing must be visible.

PASSED
UNDERSLAB INSULATION

Inspection required prior to placing slab concrete.

PASSED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

FAILED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PARTIAL
PAPER/FLASHING/WATERPROOFING

When framing, sheathing, building paper, flashing, weatherproofing of openings and window installation is complete, but before installation of any siding, wire mesh or stucco.

PARTIAL
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

FAILED
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PARTIAL
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

CANCELLED
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PARTIAL
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

FAILED
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PASSED
PLUMBING FINAL-OLD

All fixtures must be in place.

PASSED
FINAL-OLD

Final approval as per requirements on plans.

FAILED
FINAL-OLD

Final approval as per requirements on plans.

FAILED
FINAL-OLD

Final approval as per requirements on plans.

PASSED

2013-03-27

Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.