BP116915 - 106 - 6596 Applecross Road -- Scanned
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search Again| BP116915 - 106 - 6596 Applecross Road -- Scanned | |
|---|---|
| Neighbourhood: | Dover |
| Street Address: | 106 - 6596 Applecross Road -- Scanned |
| Type of Application: | Leasehold Improvements |
| File Number: | BP116915 |
| Date Application Submitted: | January 20, 2012 |
| Application Description: |
Sam's Optical-Unit 106, This permit is for a Group D, 93.65 m2, single exit permitted . Sprinkler modifications. Installing one universal washrooms in compliance with 3.8 . Ensure fire stopping at any penetration of rated fire separations. The 45 min FRR/FS roof-ceiling assembly under base building, Vertical demising wall to terminate at the 45min FRR/FS roof/ceiling assembly , 1 hr. FRR on the exterior wall installed under the base building BP112591. Description of base building under BP112591 Building C: - 6596 Applecross - 1493.46 m2 - Group E/Group A2 - Classification 3.2.2.62/3.2.2.27, Sprinklered, Fire Alarm, combustible, N & E exterior walls 1 hr. FRR and 45 min. FRR/FS demising walls, 45 min. FRR/ FS Roof-ceiling assembly.Completion of office for retail optical store |
| Application Status: | COMPLETED |
| Permit Value: | $60,000.00 |
| Builder: | MINHAS GUR |
| Issued Date: | January 27, 2012 |
| File Close Date: | April 20, 2012 |
| Expiry Date: | January 27, 2014 |
Associated Properties
| Address | Zone | More |
|---|---|---|
| 6596 APPLECROSS ROAD | CC4 | Property Report |
Process Steps
| Task | Status |
|---|---|
|
UNDERSLAB PLUMBING
Complete underslab plumbing must be visible. |
PASSED |
|
UNDERSLAB INSULATION
Inspection required prior to placing slab concrete. |
CANCELLED |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PASSED |
|
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visible for inspection. |
PARTIAL |
|
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval. |
PARTIAL |
|
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
FAILED |
|
FINAL-OLD
Final Approval as per requirements on plans. |
FAILED |
|
FINAL-OLD
Final Approval as per requirements on plans. |
PASSED
2012-04-20 |
| Map |
|---|
View in Google Earth (KML)
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

View in Google Earth (KML)