BP116913 - 204/206, 1650 Terminal Avenue N -- Scanned
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search Again| BP116913 - 204/206, 1650 Terminal Avenue N -- Scanned | |
|---|---|
| Neighbourhood: | Newcastle/Brechin |
| Street Address: | 204/206, 1650 Terminal Avenue N -- Scanned |
| Type of Application: | Leasehold Improvements |
| File Number: | BP116913 |
| Date Application Submitted: | January 20, 2012 |
| Application Description: |
Complete balance of the upper floor 488 m2, to create 2 Group D suites. No fire separations are required between suites or public corridor, refer to the Strata Plan for delineation of the units and the public corridor. Access to exit is provided throughout the floor area. Unit 204, 208.6 m2. Unit 206, 192.8m2 Part 3, Office (Group D) Building, Building classification : 3.2.2.56, combustible, 2 storey with basement, sprinklered with fire alarm. 45min FRR/FS for floor assembly and loadbearing supports. Exits shafts 45min FRR/FS. Accessible for persons with disabilities. Amended 2012-Apr-30 delete one wall, construct coat and data closet (c/w sprinkler protection) and add two dishwasher. |
| Application Status: | COMPLETED |
| Permit Value: | $315,000.00 |
| Building Area: |
488.00 M2 5,252.78 ft2 |
| Builder: | WINDLEY INVESTMENTS LTD |
| Builder: | IC MANAGEMENT CONSULTANTS LTD |
| Issued Date: | April 02, 2012 |
| File Close Date: | June 21, 2012 |
| Expiry Date: | April 02, 2014 |
Associated Properties
| Address | Zone | More |
|---|---|---|
| 1650 TERMINAL AVENUE N | COR3 | Property Report |
| 204 1650 TERMINAL AVENUE N | COR3 | Property Report |
| 206 1650 TERMINAL AVENUE N | COR3 | Property Report |
Process Steps
| Task | Status |
|---|---|
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
|
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval. |
PARTIAL |
|
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval. |
PARTIAL |
|
PLUMBING FINAL-OLD
All fixtures must be in place. |
PASSED |
|
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
PASSED |
|
FINAL-OLD
Final Approval as per requirements on plans. |
PASSED
2012-06-21 |
| Map |
|---|
View in Google Earth (KML)
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

View in Google Earth (KML)