BP116867 - 2590 Bowen Road

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP116867 - 2590 Bowen Road
Neighbourhood: Northfield    
Street Address: 2590 Bowen Road
Type of Application: Commercial / Multi / Industrial
File Number: BP116867
Date Application Submitted: December 19, 2011
Application Description: New Laird Wheaton Dealership - Part 3, Building Classification, 3.2.2.70, Group F2. Building Area for Code 2238.2m2. Sprinkered with Fire Alarm. Combustible or Non Combustible construction permitted . Non combustible provided. Two stories with interconnected floor space. Group F3 service drive through area 68.1m2. Group F2 showroom, parts, service area, tools room, and repair shop 1087.9m2. Group D offices interconnected second floor area 363.9m2. Group F2 Mezzanines 203.2m2. Mezzanines are enclosed and are 9% of the Floor area. 2 Hour fire separation between the repair garage, tool storage, fluid storage area and the remainder of the building as per BCBC 3.3.5.5. See also GHL Alternative Solution for unprotected openings in 2 hour FS. Floor assemblies are Fire Separations with FRR of 45min. Mezzanines are non combustible an require no FRR. Exits = 45 min. FRR/FS. Janitor Room FS no FRR.
X reference Foundation Permit BP117058 & all structural drawings in BP117058
Application Status: COMPLETED
Permit Value: $3,360,000.00
Builder: ISLAND WEST COAST DEVELOPMENTS
Issued Date: April 26, 2012
File Close Date: October 22, 2013

Process Steps

Task Status
FOOTING/FORMS

Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite.

PARTIAL
FOOTING/FORMS

Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite.

PARTIAL
UNDERSLAB PLUMBING

complete underslab plumbing must be visible.

PARTIAL
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PARTIAL
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PARTIAL
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PARTIAL
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PARTIAL
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PARTIAL
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PASSED
MONITORING FIELD REVIEW

A building official may attend the site from time to time during the course of construction to ascertain that the field reviews are taking place and to monitor the field reviews undertaken by the registered professional.

PARTIAL
PLUMBING FINAL-OLD

All fixtures must be in place.

PARTIAL
PLUMBING FINAL-OLD

All fixtures must be in place.

PARTIAL
PLUMBING FINAL-OLD

All fixtures must be in place.

PASSED
FINAL-OLD

Final approval as per requirements on plans.

CANCELLED
FINAL-OLD

Final approval as per requirements on plans.

PARTIAL
FINAL-OLD

Final approval as per requirements on plans.

PARTIAL
FINAL-OLD

Final approval as per requirements on plans.

PARTIAL
FINAL-OLD

Final approval as per requirements on plans.

FAILED
FINAL-OLD

Final approval as per requirements on plans.

FAILED
FINAL-OLD

Final approval as per requirements on plans.

PASSED

2013-10-22

Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.

The Information Provided within this website is for Informational Purposes Only. It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.