BP116817 - 750 Railway Avenue -- Scanned
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search Again| BP116817 - 750 Railway Avenue -- Scanned | |
|---|---|
| Neighbourhood: | Harewood |
| Street Address: | 750 Railway Avenue -- Scanned |
| Type of Application: | Single / Two Family Dwelling |
| File Number: | BP116817 |
| Date Application Submitted: | November 29, 2011 |
| Application Description: |
Constuct a two storey single family dwelling Revision December 30, 2011 Slinding glass door, man door and 8x3 window added to rear elevation. Two 4x3 windows added to the right elevation. Rock retaining walls added at front of building. Applicant changed a portion of floor to 12" O/C as noted on plan. Revision 2012-JAN-18 3pc bathroom rough-in added to basement for future suite separate hot and cold shutoffs required. |
| Application Status: | COMPLETED |
| Permit Value: | $172,573.46 |
| Building Area: |
145.47 M2 1,565.82 ft2 |
| Issued Date: | December 13, 2011 |
| File Close Date: | April 23, 2012 |
Associated Properties
| Address | Zone | More |
|---|---|---|
| 750 RAILWAY AVENUE | R5 | Property Report |
Process Steps
| Task | Status |
|---|---|
|
FOOTING / FORMS
Inspection of forms prior to any concrete being poured |
PARTIAL |
|
FOOTING / FORMS
Inspection of forms prior to any concrete being poured |
PARTIAL |
|
FOOTING / FORMS
Inspection of forms prior to any concrete being poured |
PASSED |
|
PERIMETER DRAIN
For perimeter drain , foundation walls should be damp proofed and drain tile in place with drain rock covering |
PARTIAL |
|
PERIMETER DRAIN
For perimeter drain , foundation walls should be damp proofed and drain tile in place with drain rock covering |
PASSED |
|
UNDERSLAB INSULATION
Inspection required prior to placing slab concrete |
FAILED |
|
UNDERSLAB INSULATION
Inspection required prior to placing slab concrete |
PASSED |
|
SANITARY CONNECTION
Pipe and Connection must be visible for inspection |
PASSED |
|
WATER CONNECTION
Pipe and Connection must be visable for inspection |
PASSED |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping |
FAILED |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping |
PASSED |
|
PAPER/FLASHING/WATERPROOFING
When framing, sheathing, building paper, flashing, weatherproofing of openings and window installation is complete, but before installation of any siding, wire mesh or stucco. |
PARTIAL |
|
PAPER/FLASHING/WATERPROOFING
When framing, sheathing, building paper, flashing, weatherproofing of openings and window installation is complete, but before installation of any siding, wire mesh or stucco. |
PARTIAL |
|
PAPER/FLASHING/WATERPROOFING
When framing, sheathing, building paper, flashing, weatherproofing of openings and window installation is complete, but before installation of any siding, wire mesh or stucco. |
PASSED |
|
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate & Truss Layouts required for approval |
PASSED |
|
INSULATION
Insulation and vapour barrier to be complete prior to inspection |
PARTIAL |
|
INSULATION
Insulation and vapour barrier to be complete prior to inspection |
CANCELLED |
|
INSULATION
Insulation and vapour barrier to be complete prior to inspection |
PASSED |
|
OCCUPANCY-OLD
Exterior of house must be complete including stairs, decks, handrails, porches and exterior finish |
FAILED |
|
OCCUPANCY-OLD
Exterior of house must be complete including stairs, decks, handrails, porches and exterior finish |
PASSED
2012-04-23 |
| Map |
|---|
View in Google Earth (KML)
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

View in Google Earth (KML)