BP116245 - Unit #2 - 1533 Estevan -- Scanned
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search Again| BP116245 - Unit #2 - 1533 Estevan -- Scanned | |
|---|---|
| Neighbourhood: | Newcastle/Brechin |
| Street Address: | Unit #2 - 1533 Estevan -- Scanned |
| Type of Application: | Leasehold Improvements |
| File Number: | BP116245 |
| Date Application Submitted: | June 01, 2011 |
| Application Description: |
Nesvog Meats- Combining Units 2 and 3. New Unit is #2. Group E, 409 m2, New fire resistance rating for the roof assembly 45 min FRR = one layer 5/8"Type X to existing trusses. New grease trap, relocating sinks and adding sinks, new dishwater, relocating HWT. new fixtures in existing universal washroom, One existing unisex. Washrooms determined by # of staff (12). accessible cash counter. 2 exits required Existing fire resistance rating for west demising wall = 1 hr FRR/FS and East demising wall = 2 hr FRR/FS. Existing 1957 building, combustible, unsprinklered, 2815.2m2 building with partial Firewall (non-conforming) between West units (1212.46m2) and remainder of building; centre area (669.5m2) now divided from 933.24m2 East side by 2 hr Firewall (created under equivalency).see permit 108185 |
| Application Status: | COMPLETED |
| Permit Value: | $250,000.00 |
| Building Area: |
409.00 M2 4,402.44 ft2 |
| Builder: | KOMEN CONTRACTING |
| Issued Date: | July 08, 2011 |
| File Close Date: | November 16, 2011 |
| Expiry Date: | July 08, 2013 |
Associated Properties
| Address | Zone | More |
|---|---|---|
| 1533 ESTEVAN ROAD | CC3 | Property Report |
Process Steps
| Task | Status |
|---|---|
|
UNDERSLAB PLUMBING
Complete underslab plumbing must be visible. |
PARTIAL |
|
UNDERSLAB PLUMBING
Complete underslab plumbing must be visible. |
PASSED |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
|
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval. |
PARTIAL |
|
PLUMBING FINAL-OLD
All fixtures must be in place. |
PARTIAL |
|
PLUMBING FINAL-OLD
All fixtures must be in place. |
PASSED |
|
FINAL-OLD
Final Approval as per requirements on plans. |
PARTIAL |
|
FINAL-OLD
Final Approval as per requirements on plans. |
PASSED
2011-11-16 |
| Map |
|---|
View in Google Earth (KML)
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

View in Google Earth (KML)