BP115964 - 398 Bruce Avenue - SCANNED
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search Again| BP115964 - 398 Bruce Avenue - SCANNED | |
|---|---|
| Neighbourhood: | University District |
| Street Address: | 398 Bruce Avenue - SCANNED |
| Type of Application: | Commercial / Multi / Industrial |
| File Number: | BP115964 |
| Date Application Submitted: | February 22, 2011 |
| Application Description: |
Interior Tenant Alteration to expand existing space - LITTLE GEORGE RESTAURANT Group A2 161.09 sq m 3.2.2.28 GROUP A2 one storey 321.35 sq m combustible construction permitted Jan. 30, 2012 Revisions submitted Dec 14th and Jan. 20th, NFPA - 96 hood to be moved, kitchen redesigned, bathrooms reconfigured, entry vestibule added, door at rear of suite added and one door at side of building, all existing plumbing fixtures being moved. VS June 11,2012 Revision - structural engineering for removal of post. VS |
| Application Status: | COMPLETED |
| Permit Value: | $15,000.00 |
| Issued Date: | March 28, 2011 |
| File Close Date: | October 31, 2013 |
Associated Properties
| Address | Zone | More |
|---|---|---|
| 398 BRUCE AVENUE | CC1 | Property Report |
Process Steps
| Task | Status |
|---|---|
|
FOOTING/FORMS
Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite. |
FAILED |
|
FOOTING/FORMS
Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite. |
PASSED |
|
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PASSED |
|
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PASSED |
|
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PASSED |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PASSED |
|
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
FAILED |
|
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PARTIAL |
|
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PASSED |
|
MONITORING FIELD REVIEW
A building official may attend the site from time to time during the course of construction to ascertain that the field reviews are taking place and to monitor the field reviews undertaken by the registered professional. |
PASSED |
|
FINAL-OLD
Final approval as per requirements on plans. |
CANCELLED |
|
FINAL-OLD
Final approval as per requirements on plans. |
PASSED
2013-10-31 |
| Map |
|---|
View in Google Earth (KML)
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

View in Google Earth (KML)