BP115685 - 19 - 1925 Bowen Road
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search Again| BP115685 - 19 - 1925 Bowen Road | |
|---|---|
| Neighbourhood: | Northfield |
| Street Address: | 19 - 1925 Bowen Road |
| Type of Application: | Leasehold Improvements |
| File Number: | BP115685 |
| Date Application Submitted: | October 19, 2010 |
| Application Description: |
Huong Lan Restaurant - Unit 19 (combining 18, 19, 20) -" Limited " Group A2 " Occupancy - Expansion into adjacent Unit 20 for kitchen and into Unit 18 to increase eating area for the existing restaurant. Existing wall between this unit & Unit 17 is block wall = 4 hr. FRR/FS. One hour FRR/FS between this unit and adjacent offices Unit 21. Ensure continuous fire resistance/fire separation to underside of roof deck. Adding one accessible washroom, one is existing. New NFPA 96 kitchen exhaust hood. New sinks. Two exits required. Originally built under NBC 1977, 3.2.2.33., Group E, unsprinklered, facing 3 street, 968m2 - One storey, combustible, unsprinklered building, Existing 4 hr. firewall. |
| Application Status: | COMPLETED |
| Permit Value: | $10,000.00 |
| Building Area: |
274.00 M2 2,949.31 ft2 |
| Builder: | ELDORADO DEVELOPMENT CORP LTD |
| Issued Date: | January 05, 2011 |
| File Close Date: | May 09, 2011 |
| Expiry Date: | January 04, 2013 |
Associated Properties
| Address | Zone | More |
|---|---|---|
| 1925 BOWEN ROAD | COR3 | Property Report |
Process Steps
| Task | Status |
|---|---|
|
UNDERSLAB PLUMBING
Complete underslab plumbing must be visible. |
PASSED |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PASSED |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
CANCELLED |
|
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval. |
PARTIAL |
|
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval. |
PASSED |
|
PLUMBING FINAL-OLD
All fixtures must be in place. |
FAILED |
|
PLUMBING FINAL-OLD
All fixtures must be in place. |
PASSED |
|
FINAL-OLD
Final Approval as per requirements on plans. |
FAILED |
|
FINAL-OLD
Final Approval as per requirements on plans. |
PASSED
2011-05-09 |
| Map |
|---|
View in Google Earth (KML)
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

View in Google Earth (KML)