BP115635 - 109 - 6596 Applecross Road

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP115635 - 109 - 6596 Applecross Road
Neighbourhood: Dover    
Street Address: 109 - 6596 Applecross Road
Type of Application: Leasehold Improvements
File Number: BP115635
Date Application Submitted: September 27, 2010
Application Description: Lasik MD - Unit 109 Tenant Improvement This permit is for a Group D, 2092 sq.ft. (194.35 m2), two exits required as travel distance >25 m. Sprinkler modifications. Installing two washrooms in compliance with 3.8 with one washroom being universal. Ensure fire stopping at any penetration of rated fire separations. The 45 min FRR/FS roof-ceiling assembly under base building, Vertical demising wall to terminate at the 45min FRR/FS roof/ceiling assembly , 2 hr. FRR/FS on the demising wall installed under the base building BP112591 as part of an alternative solution.

Separate permit required for signage.

Bldg C: - 6596 Applecross - 1493.46 m2 - Group E/A2 -
3.2.2.27/ 3.2.2.62, Sprinklered, Fire Alarm, combustible, N & E exposed walls face 1 hr FRR, Suite separation = 45 min. FRR/FS to underside of 45 min. FRR/FS Roof Assembly and 2 hr. FRR/FS to roof sheathing (by alternative solution (GHL) between A2 (Pho Boi) and adjacent occupancies. 1 hr FRR/FS for service rooms,
Application Status: COMPLETED
Permit Value: $105,000.00
Issued Date: November 04, 2010
File Close Date: December 23, 2010
Expiry Date: November 05, 2012

Associated Properties

Address Zone More
6596 APPLECROSS ROAD CC4 Property Report

Process Steps

Task Status
UNDERSLAB PLUMBING

Complete underslab plumbing must be visible.

PASSED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PARTIAL
FRAMING

Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval.

PARTIAL
FRAMING

Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval.

PASSED
PLUMBING FINAL-OLD

All fixtures must be in place.

PASSED
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

PASSED
OCCUPANCY-OLD PASSED

2010-12-23

FINAL-OLD

Final Approval as per requirements on plans.

FAILED
FINAL-OLD

Final Approval as per requirements on plans.

PASSED

2010-12-23

Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.