BP115273 - 6155 Metral Drive (alias 6135 Metral) (Phase 1) -- Scanned

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP115273 - 6155 Metral Drive (alias 6135 Metral) (Phase 1) -- Scanned
Neighbourhood: Pleasant Valley    
Street Address: 6155 Metral Drive (alias 6135 Metral) (Phase 1) -- Scanned
Type of Application: Commercial / Multi / Industrial
File Number: BP115273
Date Application Submitted: June 09, 2010
Application Description: 1480.60 m2 Mixed use office/multi-family building (Building A), 3 storey, combustible building with 458.64 m2 on lowest level containing 2 shell CRU's and storage , 556.54 m2 on ground floor containing 2 shell CRU's and 465.42 m2 - 4 residential units on top floor. Future permits required to complete and occupy all commercial units. Washrooms only roughed in for CRU's.

Building Classification, Group C & D: (most restrictive) Group C 3.2.2.48. up to 3 storeys, sprinklered, combustible, 3/4 hr FS/FRR for floor assemblies, mezz and supports if of combustible construction. (1 hr floor between Group C and D occupancies). 3/4 hr FS/FRR between residential suites.

Alias Address of building: 6135 Metral Drive
Allias Address of Units: (Lower Floor) 01 & 02
(Ground Floor)101 & 102
(Second Floor) 201, 202, 203 & 204
Application Status: COMPLETED
Permit Value: $1,200,000.00
Builder: RW (BOB) WALL LTD
Issued Date: November 03, 2011
File Close Date: August 02, 2012

Associated Properties

Address Zone More
6155 METRAL DRIVE COR2 Property Report
6135 METRAL DRIVE COR2 Property Report
01   6135 METRAL DRIVE COR2 Property Report
02   6135 METRAL DRIVE COR2 Property Report
101   6135 METRAL DRIVE COR2 Property Report
102   6135 METRAL DRIVE COR2 Property Report
201   6135 METRAL DRIVE COR2 Property Report
202   6135 METRAL DRIVE COR2 Property Report
203   6135 METRAL DRIVE COR2 Property Report
204   6135 METRAL DRIVE COR2 Property Report
6135 METRAL DRIVE COR2 Property Report

Process Steps

Task Status
FOOTING/FORMS

Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite.

PARTIAL
PERIMETER DRAIN

For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering.

PARTIAL
PERIMETER DRAIN

For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering.

PARTIAL
UNDERSLAB PLUMBING

complete underslab plumbing must be visible.

PARTIAL
UNDERSLAB PLUMBING

complete underslab plumbing must be visible.

PARTIAL
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PARTIAL
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visable for inspection.

PARTIAL
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PARTIAL
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PARTIAL
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PARTIAL
FINAL-OLD

Final approval as per requirements on plans.

FAILED
FINAL-OLD

Final approval as per requirements on plans.

FAILED
FINAL-OLD

Final approval as per requirements on plans.

PASSED

2012-08-02

Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.