BP115223 - 302 - 306 60 Commercial Street
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search Again| BP115223 - 302 - 306 60 Commercial Street | |
|---|---|
| Neighbourhood: | Downtown/Old City |
| Street Address: | 302 - 306 60 Commercial Street |
| Type of Application: | Leasehold Improvements |
| File Number: | BP115223 |
| Date Application Submitted: | May 25, 2010 |
| Application Description: |
Great Canadian Dollar Store - Unit 306 - 3335 sq. ft. (310m2) - Group E- Tenant improvements. Includes completion of this unit 30 for the dollar store and landlord's work in Unit 302. Unit 306: Installation of new demising wall, 1 hr. FRR/FS between this unit and the vacant unit. Includes interior finishing (millwork, flooring, painting), includes an accessible cash counter. One new accessible washroom. Service penetration (coring) within the slab for washroom only. Fire stopping system for piping transition between the parking garage level and this level by Alternative solution. Minor sprinkler changes. Occupants load 10 staff (for washroom). Unit 302: Includes work within vacant unit # 302 for service penetrations and rough-in plumbing and HVAC system only. Fire stopping system for piping transition by Alternative solution. Separate permit required for tenant. X reference BP110341.VICC, Non-combustible construction, sprinklered with fire alarm. |
| Application Status: | COMPLETED |
| Permit Value: | $80,000.00 |
| Building Area: |
310.00 M2 3,336.81 ft2 |
| Builder: | K4 COMMERCIAL INTERIORS LTD |
| Issued Date: | June 23, 2010 |
| File Close Date: | August 09, 2010 |
| Expiry Date: | June 22, 2012 |
Associated Properties
| Address | Zone | More |
|---|---|---|
| 60 COMMERCIAL STREET | DT1 | Property Report |
Process Steps
| Task | Status |
|---|---|
|
UNDERSLAB PLUMBING
Complete underslab plumbing must be visible. |
FAILED |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PASSED |
|
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visible for inspection. |
PASSED |
|
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval. |
PASSED |
|
PLUMBING FINAL-OLD
All fixtures must be in place. |
PASSED |
|
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
FAILED |
|
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
PASSED |
|
FINAL-OLD
Final Approval as per requirements on plans. |
FAILED |
|
FINAL-OLD
Final Approval as per requirements on plans. |
FAILED |
|
FINAL-OLD
Final Approval as per requirements on plans. |
PASSED
2010-08-09 |
| Map |
|---|
View in Google Earth (KML)
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

View in Google Earth (KML)