BP115014 - 300 Cottle Place
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search Again| BP115014 - 300 Cottle Place | |
|---|---|
| Neighbourhood: | Linley Valley |
| Street Address: | 300 Cottle Place |
| Type of Application: | Single / Two Family Dwelling |
| File Number: | BP115014 |
| Date Application Submitted: | March 31, 2010 |
| Application Description: |
Construct a two storey single family dwelling + suite on slab/crawlspace with attached triple garage (suspended slab). Revision October 13, 2010, Delete crawl space from plan and replace with slab on grade. Add spray foam insulation to exterior of foundation with protection for insulation all around foundation where new slab is located. External insulation will be minimum of 16" below grade, and extend horizontally 16" past slab on grade to crawlspace area. MLB |
| Application Status: | COMPLETED |
| Permit Value: | $373,534.21 |
| Building Area: |
361.99 M2 3,896.42 ft2 |
| Builder: | ARMANS HOMES |
| Issued Date: | May 27, 2010 |
| File Close Date: | February 28, 2011 |
Associated Properties
| Address | Zone | More |
|---|---|---|
| 300 COTTLE PLACE | R10 | Property Report |
Process Steps
| Task | Status |
|---|---|
|
FOOTING / FORMS
Inspection of forms prior to any concrete being poured |
PASSED |
|
PERIMETER DRAIN
For perimeter drain , foundation walls should be damp proofed and drain tile in place with drain rock covering |
PASSED |
|
UNDERSLAB PLUMBING
Complete underslab plumbing must be visible |
PASSED |
|
STORM CONNECTION
Pipe and Connection must be visible for inspection |
CANCELLED |
|
STORM CONNECTION
Pipe and Connection must be visible for inspection |
PASSED |
|
SANITARY CONNECTION
Pipe and Connection must be visible for inspection |
CANCELLED |
|
SANITARY CONNECTION
Pipe and Connection must be visible for inspection |
PASSED |
|
WATER CONNECTION
Pipe and Connection must be visable for inspection |
PASSED |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping |
PARTIAL |
|
PAPER/FLASHING/WATERPROOFING
When framing, sheathing, building paper, flashing, weatherproofing of openings and window installation is complete, but before installation of any siding, wire mesh or stucco. |
PARTIAL |
|
PAPER/FLASHING/WATERPROOFING
When framing, sheathing, building paper, flashing, weatherproofing of openings and window installation is complete, but before installation of any siding, wire mesh or stucco. |
PASSED |
|
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate & Truss Layouts required for approval |
PASSED |
|
INSULATION
Insulation and vapour barrier to be complete prior to inspection |
PASSED |
|
OCCUPANCY-OLD
Exterior of house must be complete including stairs, decks, handrails, porches and exterior finish |
PASSED
2011-02-28 |
| Map |
|---|
View in Google Earth (KML)
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

View in Google Earth (KML)