BP114242 - 2137 Bowen -- Scanned

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP114242 - 2137 Bowen -- Scanned
Neighbourhood: Northfield    
Street Address: 2137 Bowen -- Scanned
Type of Application: Commercial / Multi / Industrial
File Number: BP114242
Date Application Submitted: April 07, 2010
Application Description: Rear Addition to existing mixed used building. 5.94 m x 9.5 m= 56 m2. Removal of the existing garage and deck to be replaced with new addition. The addition includes a storage area 5.94 m x 5.79 m that is attached to CRU and a Garage that serves and is attached to the dwelling unit. The addition has an open deck that serves the residential unit. A vertical one hour FRR/FS min. required 1.5 hr provided between the garage and the dwelling unit. The roof is to be provided with a one hour FRR/FS. The east wall is to have 2 hr FRR combustible construction with non-combustible cladding.(hardiplank siding) The west wall is to be provided with a 45 min FRR. 1.5 hr FRR provided.

Existing Part 9 building, unsprinklered.
Application Status: COMPLETED
Permit Value: $42,000.00
Issued Date: December 21, 2010
File Close Date: October 28, 2011

Associated Properties

Address Zone More
2137 BOWEN ROAD COR3 Property Report

Process Steps

Task Status
FOOTING/FORMS

Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite.

PASSED
PERIMETER DRAIN

For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering.

PASSED
UNDERSLAB INSULATION

Inspection required prior to placing slab concrete.

PASSED
STORM CONNECTION

Pipe and connection must be visible for inspection.

PASSED
PAPER/FLASHING/WATERPROOFING

When framing, sheathing, building paper, flashing, weatherproofing of openings and window installation is complete, but before installation of any siding, wire mesh or stucco.

PARTIAL
PAPER/FLASHING/WATERPROOFING

When framing, sheathing, building paper, flashing, weatherproofing of openings and window installation is complete, but before installation of any siding, wire mesh or stucco.

PASSED
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PASSED
FINAL-OLD

Final approval as per requirements on plans.

FAILED
FINAL-OLD

Final approval as per requirements on plans.

PASSED

2011-10-28

Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.