BP114242 - 2137 Bowen -- Scanned
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search Again| BP114242 - 2137 Bowen -- Scanned | |
|---|---|
| Neighbourhood: | Northfield |
| Street Address: | 2137 Bowen -- Scanned |
| Type of Application: | Commercial / Multi / Industrial |
| File Number: | BP114242 |
| Date Application Submitted: | April 07, 2010 |
| Application Description: |
Rear Addition to existing mixed used building. 5.94 m x 9.5 m= 56 m2. Removal of the existing garage and deck to be replaced with new addition. The addition includes a storage area 5.94 m x 5.79 m that is attached to CRU and a Garage that serves and is attached to the dwelling unit. The addition has an open deck that serves the residential unit. A vertical one hour FRR/FS min. required 1.5 hr provided between the garage and the dwelling unit. The roof is to be provided with a one hour FRR/FS. The east wall is to have 2 hr FRR combustible construction with non-combustible cladding.(hardiplank siding) The west wall is to be provided with a 45 min FRR. 1.5 hr FRR provided. Existing Part 9 building, unsprinklered. |
| Application Status: | COMPLETED |
| Permit Value: | $42,000.00 |
| Issued Date: | December 21, 2010 |
| File Close Date: | October 28, 2011 |
Associated Properties
| Address | Zone | More |
|---|---|---|
| 2137 BOWEN ROAD | COR3 | Property Report |
Process Steps
| Task | Status |
|---|---|
|
FOOTING/FORMS
Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite. |
PASSED |
|
PERIMETER DRAIN
For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering. |
PASSED |
|
UNDERSLAB INSULATION
Inspection required prior to placing slab concrete. |
PASSED |
|
STORM CONNECTION
Pipe and connection must be visible for inspection. |
PASSED |
|
PAPER/FLASHING/WATERPROOFING
When framing, sheathing, building paper, flashing, weatherproofing of openings and window installation is complete, but before installation of any siding, wire mesh or stucco. |
PARTIAL |
|
PAPER/FLASHING/WATERPROOFING
When framing, sheathing, building paper, flashing, weatherproofing of openings and window installation is complete, but before installation of any siding, wire mesh or stucco. |
PASSED |
|
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PASSED |
|
FINAL-OLD
Final approval as per requirements on plans. |
FAILED |
|
FINAL-OLD
Final approval as per requirements on plans. |
PASSED
2011-10-28 |
| Map |
|---|
View in Google Earth (KML)
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

View in Google Earth (KML)