BP114213 - 4B - 6338 Metral Drive
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search Again| BP114213 - 4B - 6338 Metral Drive | |
|---|---|
| Neighbourhood: | Pleasant Valley |
| Street Address: | 4B - 6338 Metral Drive |
| Type of Application: | Leasehold Improvements |
| File Number: | BP114213 |
| Date Application Submitted: | July 20, 2009 |
| Application Description: |
Bark & Fitz - Group E -181.4m2 - Complete and Occupy - Installation of one "Universal" washroom to comply with Article 3.8,. 34" door into universal washroom. Ensure 24" clearance beside door on latching side of door to universal washroom. Installation of emergency lighting. Add one layer of fire rated gypsum board 5/8" Type X or Type C. to suite demising wall. Single exit. Dropping one head in washroom and two head in grooming room. New dog grooming room with one tub and roughin for future tub. 6338 Metral - Bldg C = Shell Bldg only - 2 & 1 hr FRR/FS demising walls for 5 CRUs, Future permits required to complete CRU'S; Bldg area = 1019 m2, Group A2 & Group E, One storey, 3.2.2.27, Sprinklered, combustible const. OK, Accessible, Fire alarm. Wall added to divide washing and grooming fuctions. Oct. 14, 09 VS |
| Application Status: | COMPLETED |
| Permit Value: | $85,000.00 |
| Building Area: |
181.00 M2 1,948.27 ft2 |
| Issued Date: | August 18, 2009 |
| File Close Date: | October 14, 2009 |
Associated Properties
| Address | Zone | More |
|---|---|---|
| 6334 METRAL DRIVE | CC4 | Property Report |
Process Steps
| Task | Status |
|---|---|
|
UNDERSLAB PLUMBING
Complete underslab plumbing must be visible. |
PASSED |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
FAILED |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
|
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval. |
PASSED |
|
PLUMBING FINAL-OLD
All fixtures must be in place. |
FAILED |
|
PLUMBING FINAL-OLD
All fixtures must be in place. |
PASSED |
|
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
PASSED |
|
FINAL-OLD
Final Approval as per requirements on plans. |
FAILED |
|
FINAL-OLD
Final Approval as per requirements on plans. |
PASSED
2009-10-14 |
| Map |
|---|
View in Google Earth (KML)
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

View in Google Earth (KML)