BP114020 - 2308 Rockwood

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP114020 - 2308 Rockwood
Neighbourhood: Westwood    
Street Address: 2308 Rockwood
Type of Application: Single / Two Family Dwelling
File Number: BP114020
Date Application Submitted: May 22, 2009
Application Description: for construction of a slab on grade SFD level entry, unfinished walk-out basement with attached 2 car garage.

Revision July 20/09 -structural engineer added for overheight foundation wall between house and garage. MV
Revision Oct 2/09 -adding secondary suite, finish basement. MV

BCLS Certificate of Location attached db
Application Status: COMPLETED
Permit Value: $340,694.56
Building Area: 299.00 M2
3,218.41 ft2
Builder: SKYLINE DISPLAYS OF BC INC
Issued Date: June 26, 2009
File Close Date: December 22, 2009

Associated Properties

Address Zone More
2308 ROCKWOOD PLACE R5 Property Report

Process Steps

Task Status
EXCAVATION

Excavation of soil, prior to placing forms.

PASSED
FOOTING / FORMS

Inspection of forms prior to any concrete being poured

PASSED
PERIMETER DRAIN

For perimeter drain , foundation walls should be damp proofed and drain tile in place with drain rock covering

PASSED
UNDERSLAB PLUMBING

Complete underslab plumbing must be visible

PASSED
UNDERSLAB INSULATION

Inspection required prior to placing slab concrete

PASSED
STORM CONNECTION

Pipe and Connection must be visible for inspection

PASSED
SANITARY CONNECTION

Pipe and Connection must be visible for inspection

PASSED
WATER CONNECTION

Pipe and Connection must be visable for inspection

CANCELLED
WATER CONNECTION

Pipe and Connection must be visable for inspection

PASSED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping

FAILED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping

PARTIAL
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping

CANCELLED
FRAMING

Rough in plumbing and electrical must be complete. Survey Certificate & Truss Layouts required for approval

FAILED
INSULATION

Insulation and vapour barrier to be complete prior to inspection

PASSED
OCCUPANCY-OLD

Exterior of house must be complete including stairs, decks, handrails, porches and exterior finish

FAILED
OCCUPANCY-OLD

Exterior of house must be complete including stairs, decks, handrails, porches and exterior finish

PASSED

2009-12-22

Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.

The Information Provided within this website is for Informational Purposes Only. It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.