BP113820 - 1320 Fielding Road
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search AgainBP113820 - 1320 Fielding Road | |
---|---|
Neighbourhood: | Chase River |
Street Address: | 1320 Fielding Road |
Type of Application: | Single / Two Family Dwelling |
File Number: | BP113820 |
Date Application Submitted: | March 19, 2009 |
Application Description: |
Secondary Residence (2nd of 2 on parent parcel) Construction of a two storey single family dwelling, completely finished on both levels, main floor on a crawlspace, attached double garage. (house 311.97 m2) demo permit (bp113863)- complete prior to inspections. Revisions completed: 05/26/10 KM Converted crawlspace to living space. Added footing for bearing wall. |
Application Status: | RETIRED |
Permit Value: | $301,224.73 |
Building Area: |
294.22 M2 3,166.95 ft2 |
Builder: | CEDAR VILLAGE HOLDINGS INC |
Issued Date: | March 03, 2010 |
File Close Date: | February 14, 2014 |
Expiry Date: | March 14, 2014 |
Associated Properties
Address | Zone | More |
---|---|---|
1320 FIELDING ROAD | R5 | Property Report |
Process Steps
Task | Status |
---|---|
FOOTING / FORMS
Inspection of forms prior to any concrete being poured |
PASSED |
PERIMETER DRAIN
For perimeter drain , foundation walls should be damp proofed and drain tile in place with drain rock covering |
FAILED |
PERIMETER DRAIN
For perimeter drain , foundation walls should be damp proofed and drain tile in place with drain rock covering |
PASSED |
UNDERSLAB PLUMBING
Complete underslab plumbing must be visible |
FAILED |
UNDERSLAB PLUMBING
Complete underslab plumbing must be visible |
PASSED |
UNDERSLAB INSULATION
Inspection required prior to placing slab concrete |
FAILED |
UNDERSLAB INSULATION
Inspection required prior to placing slab concrete |
PASSED |
STORM CONNECTION
Pipe and Connection must be visible for inspection |
CANCELLED |
SANITARY CONNECTION
Pipe and Connection must be visible for inspection |
CANCELLED |
WATER CONNECTION
Pipe and Connection must be visable for inspection |
CANCELLED |
MONITORING FIELD REVIEW | FAILED |
OCCUPANCY-OLD
Exterior of house must be complete including stairs, decks, handrails, porches and exterior finish |
SCHEDULED |
Map |
---|
![]() |
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.