BP113613 - 170 Skinner St (parent property is 221 Commercial)
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search AgainBP113613 - 170 Skinner St (parent property is 221 Commercial) | |
---|---|
Neighbourhood: | Downtown/Old City |
Street Address: | 170 Skinner St (parent property is 221 Commercial) |
Type of Application: | Leasehold Improvements |
File Number: | BP113613 |
Date Application Submitted: | December 22, 2008 |
Application Description: |
170 Skinner Street - " Level Two Nightclub "- Floor Area 162 m2 Converting Existing Assembly Occupancy to Nightclub on second storey. Existing building 2 storeys, Designated Heritage Building. Reno includes the entire 2nd floor level. The occupant load is 148 persons including staff. New fire alarm system. The renovation includes installation of 5 waterclosets with fully enclosed partitions. Modifying existing stairs within floor area to 2 risers. Ensure Panic hardware on exit doors. Adding layer of 5/8" Type X for 45 min FRR roof. Vertical Shafts 45 min. FRR/FS. Existing building description: Building classification: 2006 BCBC 3.2.2.25 - Group A, Division 2, 1 st storey Modern Cafe & Existing A2, 2nd floor. unsprinklered, combustible construction. 45 min. FRR/FS required for floor assemblies & load bearing walls, columns & arches. Existing 45 min FS/FRR between the 1st & 2nd storey and for the exit. |
Application Status: | COMPLETED |
Permit Value: | $77,000.00 |
Building Area: |
162.00 M2 1,743.75 ft2 |
Builder: | HAZELWOOD HOLDINGS LTD |
Issued Date: | January 30, 2009 |
File Close Date: | July 03, 2009 |
Associated Properties
Address | Zone | More |
---|---|---|
221 COMMERCIAL STREET | DT1 | Property Report |
Process Steps
Task | Status |
---|---|
UNDERSLAB PLUMBING
Complete underslab plumbing must be visible. |
SCHEDULED |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval. |
PASSED |
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PASSED |
PLUMBING FINAL-OLD
All fixtures must be in place. |
PASSED |
FINAL-OLD
Final Approval as per requirements on plans. |
PASSED
2009-07-03 |
Map |
---|
![]() |
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.