BP113613 - 170 Skinner St (parent property is 221 Commercial)

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP113613 - 170 Skinner St (parent property is 221 Commercial)
Neighbourhood: Downtown/Old City    
Street Address: 170 Skinner St (parent property is 221 Commercial)
Type of Application: Leasehold Improvements
File Number: BP113613
Date Application Submitted: December 22, 2008
Application Description: 170 Skinner Street - " Level Two Nightclub "- Floor Area 162 m2
Converting Existing Assembly Occupancy to Nightclub on second storey.
Existing building 2 storeys, Designated Heritage Building. Reno includes the entire 2nd floor level. The occupant load is 148 persons including staff. New fire alarm system. The renovation includes installation of 5 waterclosets with fully enclosed partitions. Modifying existing stairs within floor area to 2 risers. Ensure Panic hardware on exit doors. Adding layer of 5/8" Type X for 45 min FRR roof. Vertical Shafts 45 min. FRR/FS.

Existing building description:
Building classification: 2006 BCBC 3.2.2.25 - Group A, Division 2, 1 st storey Modern Cafe & Existing A2, 2nd floor. unsprinklered, combustible construction. 45 min. FRR/FS required for floor assemblies & load bearing walls, columns & arches. Existing 45 min FS/FRR between the 1st & 2nd storey and for the exit.
Application Status: COMPLETED
Permit Value: $77,000.00
Building Area: 162.00 M2
1,743.75 ft2
Builder: HAZELWOOD HOLDINGS LTD
Issued Date: January 30, 2009
File Close Date: July 03, 2009

Associated Properties

Address Zone More
221 COMMERCIAL STREET DT1 Property Report

Process Steps

Task Status
UNDERSLAB PLUMBING

Complete underslab plumbing must be visible.

SCHEDULED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PARTIAL
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PARTIAL
FRAMING

Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval.

PASSED
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PASSED
PLUMBING FINAL-OLD

All fixtures must be in place.

PASSED
FINAL-OLD

Final Approval as per requirements on plans.

PASSED

2009-07-03

Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.

The Information Provided within this website is for Informational Purposes Only. It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

Help us improve our website

Don't include private or financial information in this form.

Collection and use of your personal information
Information collected on this form is done so under the general authority of the Community Charter and Freedom of Information and Protection of Privacy Act (FOIPPA), and is protected in accordance with FOIPPA.  Personal information will only be used by authorized staff to fulfill the purpose for which it was originally collected, or for a use consistent with that purpose. Questions about the collection of your personal information may be referred to the Legislative Services Department at (250) 755-4405, or via email at foi@nanaimo.ca.
Privacy Policy