BP113597 - 6300 Hammond Bay Road & 6400 Applecross Road
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search AgainBP113597 - 6300 Hammond Bay Road & 6400 Applecross Road | |
---|---|
Neighbourhood: | Dover |
Street Address: | 6300 Hammond Bay Road & 6400 Applecross Road |
Type of Application: | Commercial / Multi / Industrial |
File Number: | BP113597 |
Date Application Submitted: | December 12, 2008 |
Application Description: |
Transit building - 343.4m2 GFA, one storey addition & renovation to 2 storeys of bldg.; inspections under THIS PERMIT- alias address 6400 Applecross Road RDN Administration Bldg. - 477.7m2 GFA, 2 storey addition and renovation, covered walkway and 35.4m2 covered bike storage & garbage enclosure; inspections under BP113867 Administration Bldg. Part 3, sprinklered , fire alarm, accessible, Group A-2 & D, 2 storey building. Building classification 2006 BCBC 3.2.2.26 & 3.2.2.54. New Building Area (BCBC) = 1221.6m2. GFA = 2309m2 Combustible construction, 45min FRR/FS floor assemblies and loadbearing supports. Interconnected floor space between upper and lower floor meets 3.2.8.2.(6). Transit Bldg. Part 3, 2 storey, sprinklered, fire alarm, accessible, Group D & F-2 repair garage, BCBC area 1037.9 m2, building classification 3.2.2.72., combustible construction, 45min FRR/FS floor assemblies and loadbearing supports. 2 hr FS between repair garage and office areas. |
Application Status: | COMPLETED |
Permit Value: | $4,402,200.00 |
Builder: | WINDLEY CONTRACTING LTD |
Issued Date: | March 05, 2009 |
File Close Date: | February 15, 2011 |
Associated Properties
Address | Zone | More |
---|---|---|
6300 HAMMOND BAY ROAD | CS1 , CS2 | Property Report |
6300 HAMMOND BAY ROAD | Property Report |
Process Steps
Task | Status |
---|---|
FOOTING/FORMS
Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite. |
PASSED |
FOOTING/FORMS
Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite. |
PASSED |
PERIMETER DRAIN
For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering. |
PASSED |
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PARTIAL |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
PARTIAL |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
PARTIAL |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
CANCELLED |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
CANCELLED |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
PARTIAL |
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PASSED |
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PASSED |
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
PARTIAL |
PLUMBING FINAL-OLD
All fixtures must be in place. |
PARTIAL |
FINAL-OLD
Final approval as per requirements on plans. |
FAILED |
FINAL-OLD
Final approval as per requirements on plans. |
FAILED |
FINAL-OLD
Final approval as per requirements on plans. |
FAILED |
FINAL-OLD
Final approval as per requirements on plans. |
PASSED
2011-02-15 |
Map |
---|
![]() |
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.