BP113457 - 2214 McCullough
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search Again| BP113457 - 2214 McCullough | |
|---|---|
| Neighbourhood: | Northfield |
| Street Address: | 2214 McCullough |
| Type of Application: | Commercial / Multi / Industrial |
| File Number: | BP113457 |
| Date Application Submitted: | October 20, 2008 |
| Application Description: |
New 356.3 sq m Part 9, Group D Occupancy, two-storey, sprinklered with fire alarm, combustible office building for Island West Coast Developments. 1 hr FS/FRR for service rooms and 45 min FS/FRR for load bearing supports. Noncombustible floor assembly with allowed combustible heavy timber glulam beam floor supports. Total gross floor area of 627.6 sq m separated into: First Storey Warehouse 150.3 sq m First Storey Office 193 sq m Second Storey Office 271 sq m |
| Application Status: | COMPLETED |
| Permit Value: | $600,000.00 |
| Builder: | ISLAND WEST COAST DEVELOPMENTS |
| Issued Date: | February 13, 2009 |
| File Close Date: | January 13, 2010 |
Associated Properties
| Address | Zone | More |
|---|---|---|
| 2214 MCCULLOUGH ROAD | I1 | Property Report |
Process Steps
| Task | Status |
|---|---|
|
FOOTING/FORMS
Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite. |
PASSED |
|
PERIMETER DRAIN
For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering. |
PASSED |
|
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PARTIAL |
|
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PARTIAL |
|
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PASSED |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
|
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
PARTIAL |
|
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PASSED |
|
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PASSED |
|
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
PARTIAL |
|
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
PASSED |
|
PLUMBING FINAL-OLD
All fixtures must be in place. |
PARTIAL |
|
PLUMBING FINAL-OLD
All fixtures must be in place. |
PASSED |
| OCCUPANCY-OLD | FAILED |
| OCCUPANCY-OLD |
PASSED
2010-01-13 |
| Map |
|---|
View in Google Earth (KML)
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

View in Google Earth (KML)