BP113249 - 261 Applegreen Avenue

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP113249 - 261 Applegreen Avenue
Neighbourhood: Harewood    
Street Address: 261 Applegreen Avenue
Type of Application: Single / Two Family Dwelling
File Number: BP113249
Date Application Submitted: August 08, 2008
Application Description: Construct a two storey single family dwelling on a crawlspace with an attached single garage.

Revision -Jan 28/09 Eliminate two windows on front (2'0x3'6), main floor closet reconfigured, Bedroom #2 window size changed to 5'0x3'0,
Master bedroom: side window deleted, add wall to wall bifold, add shower to mstr. powder room, add window to mstr. ensuite 2'0x3'6. MV

Physical File Scanned + attached Jun 15, 2009 db
BCLS Certificate of Location attached Jun 15, 2009 db
Application Status: COMPLETED
Permit Value: $120,000.00
Building Area: 124.77 M2
1,343.01 ft2
Builder: PHILIP LANDICK DEVELOPMENTS LTD
Issued Date: August 28, 2008
File Close Date: February 02, 2009

Associated Properties

Address Zone More
261 APPLEGREEN AVENUE R5 Property Report

Process Steps

Task Status
FOOTING / FORMS

Inspection of forms prior to any concrete being poured

PASSED
PERIMETER DRAIN

For perimeter drain , foundation walls should be damp proofed and drain tile in place with drain rock covering

PASSED
STORM CONNECTION

Pipe and Connection must be visible for inspection

PASSED
SANITARY CONNECTION

Pipe and Connection must be visible for inspection

PASSED
WATER CONNECTION

Pipe and Connection must be visable for inspection

PASSED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping

CANCELLED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping

PARTIAL
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping

PASSED
FRAMING

Rough in plumbing and electrical must be complete. Survey Certificate & Truss Layouts required for approval

PASSED
INSULATION

Insulation and vapour barrier to be complete prior to inspection

PASSED
OCCUPANCY-OLD

Exterior of house must be complete including stairs, decks, handrails, porches and exterior finish

PASSED

2009-02-02

Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.

The Information Provided within this website is for Informational Purposes Only. It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.