BP112748 - 1965 Island Diesel Way
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search Again| BP112748 - 1965 Island Diesel Way | |
|---|---|
| Neighbourhood: | Northfield |
| Street Address: | 1965 Island Diesel Way |
| Type of Application: | Commercial / Multi / Industrial |
| File Number: | BP112748 |
| Date Application Submitted: | April 15, 2008 |
| Application Description: |
Oct 17, 08 revision submitted to add 2nd floor. Discription below changed. VS Two storey 431.8m2 pre-fabricated office / warehouse building with 224.1m2 2nd floor, divided into three tenant spaces. 2 hr fire resistance rating required for North building face, 3/4 hr fire separation between suites. Two office suites to be completed under this permit with one "Universal" toilet room in each suite. Works & service and landscaping under this permit, foundation under BP112932. Building Classification: Part 9, "D", "F-2" occupancies, two storey, combustible and non-combustible construction, sprinklered with fire alarm system, 3/4hr FS floor assembly. BCLS Certificate of Location attached db |
| Application Status: | COMPLETED |
| Permit Value: | $431,900.00 |
| Builder: | TECHNIFIELD CONTRACTING LTD |
| Issued Date: | August 20, 2008 |
| File Close Date: | November 05, 2008 |
Associated Properties
| Address | Zone | More |
|---|---|---|
| 1965 ISLAND DIESEL WAY | I3 | Property Report |
Process Steps
| Task | Status |
|---|---|
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
|
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
CANCELLED |
|
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PASSED |
|
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
PARTIAL |
|
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
PASSED |
|
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
PARTIAL |
|
PLUMBING FINAL-OLD
All fixtures must be in place. |
PARTIAL |
|
PLUMBING FINAL-OLD
All fixtures must be in place. |
PASSED |
|
PLUMBING FINAL-OLD
All fixtures must be in place. |
PARTIAL |
| OCCUPANCY-OLD | FAILED |
| OCCUPANCY-OLD | FAILED |
| OCCUPANCY-OLD | PARTIAL |
| OCCUPANCY-OLD | FAILED |
| OCCUPANCY-OLD |
PASSED
2009-02-04 |
| Map |
|---|
View in Google Earth (KML)
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

View in Google Earth (KML)