BP112534 - 102 2520 Bowen

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP112534 - 102 2520 Bowen
Neighbourhood: Northfield    
Street Address: 102 2520 Bowen
Type of Application: Leasehold Improvements
File Number: BP112534
Date Application Submitted: February 25, 2008
Application Description: Jacuzzi Store " The Soakhouse"
Type E retail store. Construct new mezzanine 98.17 m2
Main floor area is 380 m2.
Main floor consists of a showroom, a moon room (2nd showroom), a water testing room, a storage room (c/w a washer/dryer), employee bathroom, accessible washroom and a change room. Sprinklers added and modified at lower level and below mezzanine.

Two storey 3391.59m2 (main floor 3391.59m2, 2nd floor 1240.68m2) existing building reclassified under BCBC 1998 - 3.2.2.60. Group E (lower) & D (upper) major occupancies, up to 3 storeys sprinklered with fire alarm, combustible or non-combustible construction, 45min. fire separation for floors. 45min. FRR for mezzanines and loadbearing supports if of combustible material.
Physical File Scanned + attached Aug 14, 2008 db
Application Status: COMPLETED
Permit Value: $80,000.00
Building Area: 478.18 M2
5,147.08 ft2
Builder: GREEN COAST CONTRACTING
Issued Date: April 17, 2008
File Close Date: June 19, 2008

Associated Properties

Address Zone More
2520 BOWEN ROAD I2 Property Report

Process Steps

Task Status
FOOTING/FORMS

Inspection of Forms prior to any cement being poured for footing inspection, forms must be complete and approved plans (complete with City Stamp) must be onsite.

PASSED
UNDERSLAB PLUMBING

Complete underslab plumbing must be visible.

PASSED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PARTIAL
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PASSED
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visible for inspection.

PARTIAL
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visible for inspection.

PASSED
FRAMING

Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval.

PASSED
FRAMING

Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval.

PARTIAL
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PARTIAL
PLUMBING FINAL-OLD

All fixtures must be in place.

PARTIAL
PLUMBING FINAL-OLD

All fixtures must be in place.

PASSED
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

PASSED
FINAL-OLD

Final Approval as per requirements on plans.

FAILED
FINAL-OLD

Final Approval as per requirements on plans.

FAILED
FINAL-OLD

Final Approval as per requirements on plans.

PASSED

2008-06-19

Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.