BP112529 - 722 Bowman
Neighbourhood: Harewood    
Street Address: 722 Bowman
Type of Application: Single / Two Family Dwelling
File Number: BP112529
Date Application Submitted: February 22, 2008
Application Description: For the Construction of a two storey addition to an existing two storey single family dwelling on a crawl space with detached garage.

REVISION October 06, 2008. Change footings to 16 " from 24" and foundation from 8" to 6" Delete the walkin closet and create a 5'by 2' closet in lieu of. Change inswing exterior doors to outswing doors. MLB

CLARIFICATION Oct 16, 2008. Geotech report confirms requirement of footings to be at least 18" below grade.
(See page six of approved plans showing section drawing. Insulation is shown to be 20 inches below grade, This drawing would indicate a footing of at least 26" below grade). Compliance with Section 9.12.2 of the B.C. Building Code requires Footings to be below local frost conditions. Nanaimo's local conditions dictate a minimum of 18".

REVISION January 21,2009. Change covered deck to storage/ freezer room with exterior stairs parallel to house.

Physical File Scanned + attached May 7, 2009 db
Application Status: COMPLETED
Permit Value: $52,557.00
Building Area: 53.50 M2
575.87 ft2
Issued Date: September 11, 2008
File Close Date: May 05, 2009

Associated Properties

Address Zone More
722 BOWMAN AVENUE R5 Property Report

Process Steps

Task Status
FOOTING / FORMS

Inspection of forms prior to any concrete being poured

PASSED
FOOTING / FORMS

Inspection of forms prior to any concrete being poured

PASSED
FOOTING / FORMS

Inspection of forms prior to any concrete being poured

PASSED
PERIMETER DRAIN

For perimeter drain , foundation walls should be damp proofed and drain tile in place with drain rock covering

PASSED
UNDERSLAB PLUMBING

Complete underslab plumbing must be visible

PARTIAL
UNDERSLAB PLUMBING

Complete underslab plumbing must be visible

PASSED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping

CANCELLED
PAPER/FLASHING/WATERPROOFING

When framing, sheathing, building paper, flashing, weatherproofing of openings and window installation is complete, but before installation of any siding, wire mesh or stucco.

PASSED
FRAMING

Rough in plumbing and electrical must be complete. Survey Certificate & Truss Layouts required for approval

FAILED
INSULATION

Insulation and vapour barrier to be complete prior to inspection

PASSED
INSULATION

Insulation and vapour barrier to be complete prior to inspection

PASSED
OCCUPANCY-OLD

Exterior of house must be complete including stairs, decks, handrails, porches and exterior finish

FAILED
OCCUPANCY-OLD

Exterior of house must be complete including stairs, decks, handrails, porches and exterior finish

PASSED

2009-05-05

Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.