BP112484 - 3296 Island Hwy N (3200 Island Hwy N)
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search Again| BP112484 - 3296 Island Hwy N (3200 Island Hwy N) | |
|---|---|
| Neighbourhood: | Rutherford |
| Street Address: | 3296 Island Hwy N (3200 Island Hwy N) |
| Type of Application: | Commercial / Multi / Industrial |
| File Number: | BP112484 |
| Date Application Submitted: | February 05, 2008 |
| Application Description: |
Liquor Store 6673 sq .ft. (620 m2), One storey building with unrated mezzanine 1222 sq. ft. (113.5 m2). Group E, Building Classification 3.2.2.62, combustible construction, fire alarm, sprinklered. Building area for code purposes = 620m2 with mezzanine that is 23%. Enclosed portion of the mezzanine includes the washrooms and an office which is 5.7%., a small demonstration domestic kitchen on the mezzanine (considered subsidiary to the Group E. Travel distance on the mezzanine is at the maximum permitted. Two exits provided on the main floor. The entrance is required to be accessible for persons with disabilities. (Power operated doors for entrance and exit) The accessible washrooms are provided on the mezzanine and are accessed by a lift on the stairs to comply with CAN/CSA-B355 standards. Guards, stairs and handrails to comply with BC. Building Code. 2009-09-28 - Alternative solution report for increased travel distance on the mezzanine by Murray Johnson, P. Eng. |
| Application Status: | COMPLETED |
| Permit Value: | $972,000.00 |
| Builder: | 527425 BC LTD |
| Issued Date: | November 14, 2008 |
| File Close Date: | March 23, 2010 |
Associated Properties
| Address | Zone | More |
|---|---|---|
| 3200 ISLAND HIGHWAY N | CC3 | Property Report |
Process Steps
| Task | Status |
|---|---|
|
FOOTING/FORMS
Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite. |
PASSED |
|
PERIMETER DRAIN
For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering. |
PASSED |
|
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PARTIAL |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
FAILED |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
CANCELLED |
|
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
PARTIAL |
|
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PASSED |
|
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
PARTIAL |
|
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
PASSED |
|
PLUMBING FINAL-OLD
All fixtures must be in place. |
PARTIAL |
|
PLUMBING FINAL-OLD
All fixtures must be in place. |
PASSED |
| OCCUPANCY-OLD | FAILED |
| OCCUPANCY-OLD | FAILED |
| OCCUPANCY-OLD |
PASSED
2010-03-23 |
|
FINAL-OLD
Final approval as per requirements on plans. |
CANCELLED |
|
FINAL-OLD
Final approval as per requirements on plans. |
FAILED |
| Map |
|---|
View in Google Earth (KML)
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

View in Google Earth (KML)