BP112484 - 3296 Island Hwy N (3200 Island Hwy N)

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP112484 - 3296 Island Hwy N (3200 Island Hwy N)
Neighbourhood: Rutherford    
Street Address: 3296 Island Hwy N (3200 Island Hwy N)
Type of Application: Commercial / Multi / Industrial
File Number: BP112484
Date Application Submitted: February 05, 2008
Application Description: Liquor Store 6673 sq .ft. (620 m2), One storey building with unrated mezzanine 1222 sq. ft. (113.5 m2). Group E, Building Classification 3.2.2.62, combustible construction, fire alarm, sprinklered. Building area for code purposes = 620m2 with mezzanine that is 23%. Enclosed portion of the mezzanine includes the washrooms and an office which is 5.7%., a small demonstration domestic kitchen on the mezzanine (considered subsidiary to the Group E. Travel distance on the mezzanine is at the maximum permitted. Two exits provided on the main floor. The entrance is required to be accessible for persons with disabilities. (Power operated doors for entrance and exit) The accessible washrooms are provided on the mezzanine and are accessed by a lift on the stairs to comply with CAN/CSA-B355 standards. Guards, stairs and handrails to comply with BC. Building Code.

2009-09-28 - Alternative solution report for increased travel distance on the mezzanine by Murray Johnson, P. Eng.
Application Status: COMPLETED
Permit Value: $972,000.00
Builder: 527425 BC LTD
Issued Date: November 14, 2008
File Close Date: March 23, 2010

Associated Properties

Address Zone More
3200 ISLAND HIGHWAY N CC3 Property Report

Process Steps

Task Status
FOOTING/FORMS

Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite.

PASSED
PERIMETER DRAIN

For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering.

PASSED
UNDERSLAB PLUMBING

complete underslab plumbing must be visible.

PARTIAL
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

FAILED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PARTIAL
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

CANCELLED
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visable for inspection.

PARTIAL
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PASSED
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

PARTIAL
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

PASSED
PLUMBING FINAL-OLD

All fixtures must be in place.

PARTIAL
PLUMBING FINAL-OLD

All fixtures must be in place.

PASSED
OCCUPANCY-OLD FAILED
OCCUPANCY-OLD FAILED
OCCUPANCY-OLD PASSED

2010-03-23

FINAL-OLD

Final approval as per requirements on plans.

CANCELLED
FINAL-OLD

Final approval as per requirements on plans.

FAILED
Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.