BP112445 - 325 Hecate -- Scanned

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP112445 - 325 Hecate -- Scanned
Neighbourhood: Downtown/Old City    
Street Address: 325 Hecate -- Scanned
Type of Application: Commercial / Multi / Industrial
File Number: BP112445
Date Application Submitted: January 25, 2008
Application Description: Oak Tree Manor
66 units Senior's Rental Residential Bldg
4 Storey, Combustible,sprinklered to NFPA 13R and NFPA 13 in parking garage, fire alarm,combustible Group C (residential) with Group F3 (Storage Garage). Subsidiary occupancies to Group C are dining room, activity room, lounge. Group C, Building area = 1198 m2 x 3 storeys & Group F3 = 915m2. Bldg description 3.2.2.45. Floor assemblies 1 Hour FRR/FS, 50 STM. Parking storage garage 1.5 hr. FRR/FS for exits & between other occupancies . Vestibule 0 hr. FS required to parkade. Duct shafts, 45 min FRR/FS, Exits 1 hour FRR/FS, Residential Suites doors only 20 min ULC labelled FPR. other door 45min FPR. 1 hr public cooridor to suites. Accessible to front entrance. Alternative solutions: Via water curtain sprinkler system for exit exposure for rear exit stairs & exit adjacent to Robarts Street .
revised alternative solutions report for the dated July 9, 2008 accepted subject to: see attachments
Doreen has file Oct 16 2009
Application Status: COMPLETED
Permit Value: $5,300,000.00
Builder: MAPLE-REINDERS INC
Issued Date: June 04, 2008
File Close Date: October 13, 2009

Associated Properties

Address Zone More
325 HECATE STREET R15 Property Report

Process Steps

Task Status
FOOTING/FORMS

Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite.

PASSED
PERIMETER DRAIN

For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering.

FAILED
PERIMETER DRAIN

For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering.

PASSED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

CANCELLED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

CANCELLED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

CANCELLED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PARTIAL
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

CANCELLED
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visable for inspection.

PARTIAL
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PARTIAL
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PASSED
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PARTIAL
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PARTIAL
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PARTIAL
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PARTIAL
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PASSED
MONITORING FIELD REVIEW

A building official may attend the site from time to time during the course of construction to ascertain that the field reviews are taking place and to monitor the field reviews undertaken by the registered professional.

PARTIAL
MONITORING FIELD REVIEW

A building official may attend the site from time to time during the course of construction to ascertain that the field reviews are taking place and to monitor the field reviews undertaken by the registered professional.

PARTIAL
MONITORING FIELD REVIEW

A building official may attend the site from time to time during the course of construction to ascertain that the field reviews are taking place and to monitor the field reviews undertaken by the registered professional.

PARTIAL
MONITORING FIELD REVIEW

A building official may attend the site from time to time during the course of construction to ascertain that the field reviews are taking place and to monitor the field reviews undertaken by the registered professional.

PARTIAL
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

PASSED
PLUMBING FINAL-OLD

All fixtures must be in place.

PASSED
OCCUPANCY-OLD CANCELLED
OCCUPANCY-OLD FAILED
OCCUPANCY-OLD PASSED

2009-10-13

Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.

The Information Provided within this website is for Informational Purposes Only. It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.