Date Application Submitted: January 15, 2008
Application Description: Jim Pattison Hyundai - 42.3m2 showroom additions under existing canopies and interior/exterior renovation. Work includes switching washbasins in washrooms on upper with lower floor. Ensure lower floor washroom meet accessibility requirements.

Existing 2 storey, sprinklered (by Bylaw, No Fire Alarm System), combustible construction, Part 3, F2/D/E Building, existing 608m2 + 42.3m2 addition = 650.3m2, Building Classification 2006 BCBC, 3.2.2.61. governs, 45min FRR/FS for floor assemblies and 45min. FRR for loadbearing bearing supports.

April 30, 2008 Wired glass windows in existing 2nd floor fire separation have 45 min. FPR and may remain - as per Architect. VS

Physical File Scanned + attached Apr 1, 2009 db
Application Status: COMPLETED
Permit Value: $225,000.00
Building Area: 42.30 M2
455.31 ft2
Builder: ISLAND WEST COAST HOMES LTD
Issued Date: April 11, 2008
File Close Date: September 24, 2008

Associated Properties

Address Zone More
4123 WELLINGTON ROAD COR3 Property Report

Process Steps

Task Status
FOOTING/FORMS

Inspection of forms prior to any concrete being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite.

PASSED
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visable for inspection.

FAILED
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PASSED
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PASSED
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

PASSED
PLUMBING FINAL-OLD

All fixtures must be in place.

PASSED
FINAL-OLD

Final approval as per requirements on plans.

FAILED
FINAL-OLD

Final approval as per requirements on plans.

PASSED

2008-09-24

Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.