BP112182 - 103 - 1808 Bowen Rd
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search Again| BP112182 - 103 - 1808 Bowen Rd | |
|---|---|
| Neighbourhood: | Northfield |
| Street Address: | 103 - 1808 Bowen Rd |
| Type of Application: | Leasehold Improvements |
| File Number: | BP112182 |
| Date Application Submitted: | October 31, 2007 |
| Application Description: |
Island Optimal Health & Performance (rehab facility) "D"-class - approx. 141.8m2 gross floor area; tenant improvement includes: 3 new clinic treatment rooms, 2 new change rooms with showers (one of which is accessible). 2 relocated sprinkler heads + 2 new sprinkler heads. Demising walls shall be continuous 1 hour FRR fire separations. Fire resistance rating & continuous fire separation shall be maintained for the floor assembly above, & supporting structure. New or replaced ratings shall be minimum 1 hour FRR. 1404m2 Sprinklered, combustible or non-combustible building with fire alarm 92 BCBC - 3.2.2.43, 45min. FRR for floor assemblies & supporting members. Physical File Scanned + attached Feb 01, 2008 dlt |
| Application Status: | COMPLETED |
| Permit Value: | $10,000.00 |
| Issued Date: | November 21, 2007 |
| File Close Date: | January 28, 2008 |
Associated Properties
| Address | Zone | More |
|---|---|---|
| 1808 BOWEN ROAD | COR3 | Property Report |
Process Steps
| Task | Status |
|---|---|
|
UNDERSLAB PLUMBING
Complete underslab plumbing must be visible. |
PASSED |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PASSED |
|
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visible for inspection. |
PASSED |
|
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval. |
PASSED |
|
PLUMBING FINAL-OLD
All fixtures must be in place. |
PARTIAL |
|
PLUMBING FINAL-OLD
All fixtures must be in place. |
PASSED |
|
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
PARTIAL |
|
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
PASSED |
|
FINAL-OLD
Final Approval as per requirements on plans. |
PARTIAL |
|
FINAL-OLD
Final Approval as per requirements on plans. |
PARTIAL |
|
FINAL-OLD
Final Approval as per requirements on plans. |
PASSED
2008-01-28 |
| Map |
|---|
View in Google Earth (KML)
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

View in Google Earth (KML)