BP112114 - 2121 Boxwood

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP112114 - 2121 Boxwood
Neighbourhood: Northfield    
Street Address: 2121 Boxwood
Type of Application: Commercial / Multi / Industrial
File Number: BP112114
Date Application Submitted: October 05, 2007
Application Description: Edgewood Treatment Facility. Permit includes on-site civil work on this property and at 2113 Boxwood.
Two storey addition to the west side of building. Total floor area added = 592 sq. m
New building area including this addition (Phase 2) = 3035 sq. m.
Part 3, sprinklered, fire alarm system, 2 storey, combustible construction, Group C, Building Re-Classification: 3.2.2.45., Corridors 1 hr. FRR/FS, doors opening into the corridor to be 45 min FPR with self closing devices, 1 hr. FRR/FS/ 50 STM between sleeping room and other occupancies. Doors of 20 min FPR/self closing, for sleeping rooms only that open into the public corridor. All other doors opening into the public corridor = 45 min. FPR with self closing devices.

COVENANT REGISTERED 2008-01-13
Application Status: COMPLETED
Permit Value: $1,050,000.00
Builder: TECTONICA MANAGEMENT INC
Issued Date: January 02, 2008
File Close Date: September 08, 2008

Associated Properties

Address Zone More
2121 BOXWOOD ROAD CS1 Property Report
2113 BOXWOOD ROAD CS1 Property Report

Process Steps

Task Status
PERIMETER DRAIN

For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering.

PASSED
UNDERSLAB PLUMBING

complete underslab plumbing must be visible.

PARTIAL
UNDERSLAB PLUMBING

complete underslab plumbing must be visible.

PARTIAL
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

SCHEDULED
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visable for inspection.

CANCELLED
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visable for inspection.

CANCELLED
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visable for inspection.

PARTIAL
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

CANCELLED
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PASSED
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PARTIAL
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

PARTIAL
PLUMBING FINAL-OLD

All fixtures must be in place.

PARTIAL
OCCUPANCY-OLD PARTIAL
OCCUPANCY-OLD PASSED

2008-09-08

FINAL-OLD

Final approval as per requirements on plans.

FAILED
Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.