BP111988 - 2109 Meredith - future address 2115 Meredith -- Scanned

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP111988 - 2109 Meredith - future address 2115 Meredith -- Scanned
Neighbourhood: Northfield    
Street Address: 2109 Meredith - future address 2115 Meredith -- Scanned
Type of Application: Commercial / Multi / Industrial
File Number: BP111988
Date Application Submitted: August 31, 2007
Application Description: Multi-residential Development - Phase 1 = Bldg A & Amenity Bldg of 3 Phases. 8 unit, 678m2, 3 storey, bldg with 3/4 hr fire separation for suites, floors, corridors, lobby & elevator. Separate 111.5m2, 2 storey Amenity bldg with 3/4 hr F.S.for elevator service room, no F.S. for elevator lift. 'Universal' washroom on upper floor.
Bldg Classifications:
Bld A - 3.2.2.48., Group C, 3 storey, <1800m2, sprinklered with fire alarm system, combustible construction, 3/4 hr fire separation for floors & 3/4 hr fire resistance rating for loadbearing supports. Inspections for this bldg (2115 Meredith) is under this permit (#111988)
Amenity Bldg - 3.2.2.27, Group A-2, 2 storey, <600m2, sprinklered with fire alarm system, combustible constr, no F.S/F.R.R. required btwn floors, fire separation with 0 FRR required between stairwell from upper floor & main floor. Inspections for this building (2109) Meredith under permit #112521. Revisions Jun 4, 08 VS
Application Status: COMPLETED
Permit Value: $1,500,000.00
Builder: REGA PROPERTIES LTD
Issued Date: March 31, 2008
File Close Date: October 28, 2009

Associated Properties

Address Zone More
101   2115 MEREDITH ROAD COR1 Property Report

Process Steps

Task Status
FOOTING/FORMS

Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite.

PASSED
PERIMETER DRAIN

For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering.

PASSED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

CANCELLED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PARTIAL
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PARTIAL
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PARTIAL
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visable for inspection.

PARTIAL
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visable for inspection.

CANCELLED
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PARTIAL
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PASSED
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PARTIAL
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PARTIAL
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PASSED
MONITORING FIELD REVIEW

A building official may attend the site from time to time during the course of construction to ascertain that the field reviews are taking place and to monitor the field reviews undertaken by the registered professional.

CANCELLED
MONITORING FIELD REVIEW

A building official may attend the site from time to time during the course of construction to ascertain that the field reviews are taking place and to monitor the field reviews undertaken by the registered professional.

PARTIAL
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

FAILED
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

PASSED
PLUMBING FINAL-OLD

All fixtures must be in place.

FAILED
PLUMBING FINAL-OLD

All fixtures must be in place.

PASSED
OCCUPANCY-OLD FAILED
OCCUPANCY-OLD PASSED

2009-10-28

Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.