BP111881 - 347 Seventh Street - Scanned
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search Again| BP111881 - 347 Seventh Street - Scanned | |
|---|---|
| Neighbourhood: | Harewood |
| Street Address: | 347 Seventh Street - Scanned |
| Type of Application: | Commercial / Multi / Industrial |
| File Number: | BP111881 |
| Date Application Submitted: | August 09, 2006 |
| Application Description: |
Plans are rolled x reference BP110534 for Phase 1 (foundation)and files Phase 2 of Bp 110534 Pacific Gardens Co-Housing Project- 25 dwelling units - 3 storey, Group C, Sprinklered to NFPA 13 (by equivalency) with fire alarm system. Building classification 3.2.2.45 , Building area =1754m2 1st storey = 893.88, 2nd storey, 1645.26m2, 3rd storey = 1302m2, total area of dwelling units only = 2606.8 m2. Floor assemblies, 1 hr. FRR/FS floors, 1 hr. FRR/FS public corridor, 1 hr FRR for load bearing supports, 1 hr. FRR/FS for roof assembly. Self-closing devices to comply with 3.1.8.11. Fire dampers to 3.1.8.7. 20 min. labelled door assembly dwelling units. 45 min. labelled doors/closures in 1 hr. FRR/FS. ULC Labelled door/closures. Equivalency Report by Gage Babcock & Associates Ltd. |
| Application Status: | COMPLETED |
| Permit Value: | $4,320,000.00 |
| Builder: | 553080 BC LTD |
| Builder: | GEORGIA VIEW HOME BUILDERS LTD |
| Issued Date: | April 21, 2008 |
| File Close Date: | January 07, 2010 |
Process Steps
| Task | Status |
|---|---|
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
CANCELLED |
|
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
CANCELLED |
|
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PARTIAL |
|
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
CANCELLED |
|
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
CANCELLED |
|
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
CANCELLED |
|
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PARTIAL |
|
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
CANCELLED |
| OCCUPANCY-OLD | CANCELLED |
| OCCUPANCY-OLD | FAILED |
| OCCUPANCY-OLD | CANCELLED |
| OCCUPANCY-OLD |
PASSED
2009-09-04 |
| Map |
|---|
View in Google Earth (KML)
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

View in Google Earth (KML)