BP111825 - #130 & #140 - 2124 Bowen Road

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP111825 - #130 & #140 - 2124 Bowen Road
Neighbourhood: Northfield    
Street Address: #130 & #140 - 2124 Bowen Road
Type of Application: Leasehold Improvements
File Number: BP111825
Date Application Submitted: July 20, 2007
Application Description: Park Place Sleep Clinic - 246.7m2 "D" occupancy. Tenant improvements includes sprinkler heads moved, lowered and added, one "universal" washroom with "accessible" shower, one other washroom with shower, kitchen, laundry room, 4 sleep rooms. Existing 1 hr FS/FRR between main floor "D" and second floor "C" occupancies. No vertical FS/FRR between suites of "D" occupancy required.

Building Classification: 3.2.2.54. or 3.2.2.48. Group D / C occupancy, 3 storey with parking garage below as separate building. Sprinklered with fire alarm, combustible construction ok.

Sept. 26, 2007 - "universal" washroom layout changed. VS
Oct. 04 - BI does not believe change proposed complies with code. New idea for layout sent to Gord, no response. Gord says PI and plumber are working out issue. VS
Application Status: COMPLETED
Permit Value: $125,000.00
Builder: MOUNTAIN VISTA PROPERTIES LTD
Issued Date: September 26, 2007
File Close Date: December 20, 2007

Associated Properties

Address Zone More
130   2124 BOWEN ROAD COR2 Property Report
140   2124 BOWEN ROAD COR2 Property Report

Process Steps

Task Status
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

FAILED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PASSED
FRAMING

Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval.

FAILED
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

FAILED
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PARTIAL
PLUMBING FINAL-OLD

All fixtures must be in place.

FAILED
PLUMBING FINAL-OLD

All fixtures must be in place.

PARTIAL
PLUMBING FINAL-OLD

All fixtures must be in place.

FAILED
PLUMBING FINAL-OLD

All fixtures must be in place.

PASSED
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

FAILED
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

PARTIAL
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

FAILED
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

PASSED
FINAL-OLD

Final Approval as per requirements on plans.

CANCELLED
FINAL-OLD

Final Approval as per requirements on plans.

FAILED
FINAL-OLD

Final Approval as per requirements on plans.

PASSED

2007-12-21

Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.