BP111762 - 2121 Boxwood Road
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search Again| BP111762 - 2121 Boxwood Road | |
|---|---|
| Neighbourhood: | Northfield |
| Street Address: | 2121 Boxwood Road |
| Type of Application: | Commercial / Multi / Industrial |
| File Number: | BP111762 |
| Date Application Submitted: | July 09, 2007 |
| Application Description: |
256 m2 additions to existing building - Phase 1 of 2 phases Edgewood Treatment Facility (Phase 1) 1 storey addition of 171 sq.m. to east side of building (new offices lounge area, and group room, washrooms.) and new addition to entrance of 85 sq.m. Total area of additions= 256 sq.m. New building area including this addition (Phase 1) = 2616.8 sq. m. Part 3, sprinklered, fire alarm system, 2 storey, combustible construction, Group C, Building Re-Classification: 3.2.2.45., Corridors 1 hr. FRR/FS, doors opening into the corridor to be 45 min FPR with self closing devices, 1 hr. FRR/FS/ 50 STM between sleeping room and other occupancies. Doors of 20 min FRP/self closing, for sleeping rooms only that open into the public corridor. All other doors opening into the public corridor = 45min FPR. East exposed building face 45min FRR. ADDED MARCH 12, 2008, Mechanical ,plumbing and fire suppression for field review by L Grant Undershute, P.Eng (B1,B2) |
| Application Status: | COMPLETED |
| Permit Value: | $500,000.00 |
| Builder: | TECTONICA MANAGEMENT INC |
| Issued Date: | September 13, 2007 |
| File Close Date: | June 15, 2009 |
Associated Properties
| Address | Zone | More |
|---|---|---|
| 2121 BOXWOOD ROAD | CS1 | Property Report |
Process Steps
| Task | Status |
|---|---|
|
FOOTING/FORMS
Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite. |
PASSED |
|
PERIMETER DRAIN
For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering. |
PASSED |
|
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PARTIAL |
|
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PARTIAL |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
|
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
PARTIAL |
|
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
PARTIAL |
|
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
PARTIAL |
|
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
PARTIAL |
|
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PARTIAL |
|
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PASSED |
|
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PARTIAL |
|
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PASSED |
|
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
PARTIAL |
|
PLUMBING FINAL-OLD
All fixtures must be in place. |
PARTIAL |
|
PLUMBING FINAL-OLD
All fixtures must be in place. |
PARTIAL |
|
PLUMBING FINAL-OLD
All fixtures must be in place. |
PARTIAL |
| OCCUPANCY-OLD | PARTIAL |
| OCCUPANCY-OLD |
PASSED
2008-03-03 |
|
FINAL-OLD
Final approval as per requirements on plans. |
PARTIAL |
|
FINAL-OLD
Final approval as per requirements on plans. |
PASSED
2009-06-15 |
| Map |
|---|
View in Google Earth (KML)
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

View in Google Earth (KML)