BP111665 - 639 Seventh (Parent) 812 Brookfield Phase 2 SL4 VIS6562 -- Scanned

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP111665 - 639 Seventh (Parent) 812 Brookfield Phase 2 SL4 VIS6562 -- Scanned
Neighbourhood: Harewood    
Street Address: 639 Seventh (Parent) 812 Brookfield Phase 2 SL4 VIS6562 -- Scanned
Type of Application: Commercial / Multi / Industrial
File Number: BP111665
Date Application Submitted: June 15, 2007
Application Description: Oakhills Vista - 27 unit multi-family site Phase 2 - 4 Units of a Multi Family Development.
Cross reference BP11080 for On-Site Service Permit. Unit 4,5,6,7 are one storey single family dwelling with daylight finished basements and attached garage.

812 Brookfield Dr. (unit 4) 175.1m2GFA + 39.8m2 garage. Inspections tasks under BP111665
816 Brookfield Dr. (unit 5) 175.1m2GFA + 39.8m2 garage. Inspection tasks under BP111701
820 Brookfield Dr. (unit 6) 175.1m2GFA + 39.8m2 garage. Inspection tasks under BP111702
824 Brookfield Dr. (unit 7) 175.1m2GFA + 39.8m2 garage. Inspection tasks under BP111703

Dec. 20, 2007 - 16.5 sq ft bump out added to great room in units 4 & 7. VS
Jan. 21, 2008 - 16.5 sq ft bump out added to great room in units 5 & 6. VS
Application Status: COMPLETED
Permit Value: $900,000.00
Builder: OAKHILLS VISTA DEVELOPMENTS LTD
Issued Date: August 16, 2007
File Close Date: May 21, 2008

Associated Properties

Address Zone More
812 BROOKFIELD DRIVE R6 Property Report
625 SEVENTH STREET R6 Property Report

Process Steps

Task Status
FOOTING/FORMS

Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite.

PASSED
PERIMETER DRAIN

For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering.

PARTIAL
UNDERSLAB PLUMBING

complete underslab plumbing must be visible.

PASSED
STORM CONNECTION

Pipe and connection must be visible for inspection.

PASSED
SANITARY CONNECTION

Pipe and connection must be visible for inspection.

PASSED
WATER CONNECTION

Pipe and connection must be visible for inspection.

PASSED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PASSED
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

FAILED
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

FAILED
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PASSED
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PASSED
OCCUPANCY-OLD FAILED
OCCUPANCY-OLD PASSED

2008-05-21

Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.