BP111660 - 205 Shiloh

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP111660 - 205 Shiloh
Neighbourhood: Westwood    
Street Address: 205 Shiloh
Type of Application: Single / Two Family Dwelling
File Number: BP111660
Date Application Submitted: June 14, 2007
Application Description: Construct a two-storey single family dwelling with a finished basement (except for 340 sq. ft.) on slab with an attached double garage.

Revisions.

Applicant has taken engineers schedules to revise foundation no longer icf. He will bring in new plans to show changes to cross sections and elevations.
July 25, 2007 DKF

July 26th, 2007 Revisions include the elimination of one window, the installation of a rear patio door. Retaining wall has been moved and ICF's have been replaced with a standard concrete foundation.

Nov 27, 2007 Owner revised lower floor, portion of rec room to bedroom. Floor beam and footings supporting the upper floor have been changed in the rec room area. See letter dated Nov 29, 2007 from S.M. Mahon at Herold Engineering re: footings. Gary P.
Application Status: COMPLETED
Permit Value: $250,000.00
Building Area: 349.70 M2
3,764.14 ft2
Issued Date: July 24, 2007
File Close Date: August 20, 2008

Associated Properties

Address Zone More
205 SHILOH DRIVE R10 Property Report

Process Steps

Task Status
FOOTING / FORMS

Inspection of forms prior to any concrete being poured

CANCELLED
FOOTING / FORMS

Inspection of forms prior to any concrete being poured

PASSED
PERIMETER DRAIN

For perimeter drain , foundation walls should be damp proofed and drain tile in place with drain rock covering

PASSED
UNDERSLAB PLUMBING

Complete underslab plumbing must be visible

FAILED
UNDERSLAB PLUMBING

Complete underslab plumbing must be visible

PASSED
STORM CONNECTION

Pipe and Connection must be visible for inspection

PASSED
SANITARY CONNECTION

Pipe and Connection must be visible for inspection

PASSED
WATER CONNECTION

Pipe and Connection must be visable for inspection

PASSED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping

FAILED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping

PARTIAL
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping

PARTIAL
PAPER/FLASHING/WATERPROOFING

When framing, sheathing, building paper, flashing, weatherproofing of openings and window installation is complete, but before installation of any siding, wire mesh or stucco.

PASSED
FRAMING

Rough in plumbing and electrical must be complete. Survey Certificate & Truss Layouts required for approval

PASSED
INSULATION

Insulation and vapour barrier to be complete prior to inspection

FAILED
INSULATION

Insulation and vapour barrier to be complete prior to inspection

PASSED
OCCUPANCY-OLD

Exterior of house must be complete including stairs, decks, handrails, porches and exterior finish

FAILED
OCCUPANCY-OLD

Exterior of house must be complete including stairs, decks, handrails, porches and exterior finish

PASSED

2008-08-20

Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.

The Information Provided within this website is for Informational Purposes Only. It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.