BP111571 - 2286 Kingsford
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search Again| BP111571 - 2286 Kingsford | |
|---|---|
| Neighbourhood: | Chase River |
| Street Address: | 2286 Kingsford |
| Type of Application: | Single / Two Family Dwelling |
| File Number: | BP111571 |
| Date Application Submitted: | May 24, 2007 |
| Application Description: |
Construct a two-storey single family dwelling on slab with built-in double garage. Revision submitted July 6, 2007 1) Changing from crawlspace to slab for full basement. 2) Adding wet- bar. 3) Changing from finished to unfinished for most of basement. 4) Finishing 3- piece bathroom in basement. AG Revision submitted Jan 17, 2008 1) Finishing basement with legal suite. 2) Changing removing windows on right side. 3) Adding wet bar. AG Revision submitted June9, 2008 - Adding washing machine for suite. AG **2008-JUN-12 - BP NOT TO BE COMPLETED UNTIL FINAL INSEPCTION FOR REVISION IS COMPLETE |
| Application Status: | COMPLETED |
| Permit Value: | $303,948.41 |
| Building Area: |
321.54 M2 3,461.02 ft2 |
| Builder: | DEEP COVE DEVELOPMENTS LTD |
| Issued Date: | June 26, 2007 |
| File Close Date: | June 09, 2008 |
Associated Properties
| Address | Zone | More |
|---|---|---|
| 2286 KINGSFORD PLACE | R5 | Property Report |
Process Steps
| Task | Status |
|---|---|
|
FOOTING / FORMS
Inspection of forms prior to any concrete being poured |
PASSED |
|
PERIMETER DRAIN
For perimeter drain , foundation walls should be damp proofed and drain tile in place with drain rock covering |
PARTIAL |
|
UNDERSLAB PLUMBING
Complete underslab plumbing must be visible |
PASSED |
|
UNDERSLAB INSULATION
Inspection required prior to placing slab concrete |
PASSED |
|
STORM CONNECTION
Pipe and Connection must be visible for inspection |
PASSED |
|
SANITARY CONNECTION
Pipe and Connection must be visible for inspection |
PASSED |
|
WATER CONNECTION
Pipe and Connection must be visable for inspection |
PASSED |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping |
CANCELLED |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping |
PARTIAL |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping |
PASSED |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping |
PASSED |
|
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate & Truss Layouts required for approval |
FAILED |
|
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate & Truss Layouts required for approval |
FAILED |
|
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate & Truss Layouts required for approval |
CANCELLED |
|
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate & Truss Layouts required for approval |
PASSED |
|
INSULATION
Insulation and vapour barrier to be complete prior to inspection |
PASSED |
|
PLUMBING FINAL-OLD
All fixtures must be in place for inspection |
PASSED |
|
OCCUPANCY-OLD
Exterior of house must be complete including stairs, decks, handrails, porches and exterior finish |
FAILED |
|
OCCUPANCY-OLD
Exterior of house must be complete including stairs, decks, handrails, porches and exterior finish |
PASSED
2008-06-09 |
| Map |
|---|
View in Google Earth (KML)
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

View in Google Earth (KML)