BP111366 - 5100 Rutherford Rd
Neighbourhood: Rutherford    
Street Address: 5100 Rutherford Rd
Type of Application: Garage / Carport Permit
File Number: BP111366
Date Application Submitted: April 02, 2007
Application Description: Construct a 27 x 23 ft. garage/covered walkway addition and 13 x 36 ft covered front entry addition to existing single family dwelling.

See cancelled BP109163 & BP109867

Revision December 12, 2007

Timber framed entrance, windows removed from garage. DKF
Application Status: COMPLETED
Permit Value: $27,249.63
Building Area: 37.62 M2
404.94 ft2
Builder: M J CHAHLEY CONSTRUCTION GROUP LTD
Issued Date: May 08, 2007
File Close Date: February 13, 2008

Associated Properties

Address Zone More
5100 RUTHERFORD ROAD R10 Property Report

Process Steps

Task Status
LATERAL BRACING & SHEATHING

All nailing and blocking associated with braced wall panels to be completed for this inspection. Wood-based interior braced wall panels to be sheathed. Exterior braced wall panel locations to be clearly marked out on the interior and exterior. Interior braced wall panels to be clearly marked so their location can be seen now and later at the time of INTERIOR BRACED WALL PANEL INSPECTION. Additional anchor bolts shall be installed two per braced wall panel where a building contains framed walls supporting more than two floors.

COMPLETED
FOOTING/FORMS

Inspection of forms prior to any cement being poured . For footing inspection, forms must be complete and approved plans (complete with City Stamp) must be onsite.

PASSED
PERIMETER DRAIN

For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering.

PASSED
PAPER/FLASHING/WATERPROOFING

When framing, sheathing, building paper, flashing, weatherproofing of openings and window installation is complete, but before installation of any siding, wire mesh or stucco.

PASSED
FRAMING

Rough-in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PARTIAL
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PARTIAL
FINAL-OLD

Final Approval as per requested on plans.

PASSED

2008-02-13

Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.