BP111296 - 2363 Cienar Drive
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search Again| BP111296 - 2363 Cienar Drive | |
|---|---|
| Neighbourhood: | Diver Lake |
| Street Address: | 2363 Cienar Drive |
| Type of Application: | Commercial / Multi / Industrial |
| File Number: | BP111296 |
| Date Application Submitted: | March 09, 2007 |
| Application Description: |
Addition to warehouse 25'.0' x 80'-0" = 2000 sq.ft. (185.8m2) to south side of north building. Two new washrooms in existing portion of building on main floor and relocating walls in the existing 45 min exit enclosure . existing 45min FRR for the floor assembly and second floor. Group F Division 2. Unsprinklered, Two storeys, Part 3. Building classification 3.2.2.71 (780.36m2); East wall face: 2hr FRR required, achieved by Spray foam, Cafco Blaze-Shield HP, ULC BXUVC.W801; West wall face: 45min FRR required, achieved by Spray foam, Cafco Blaze-Shield HP, ULC BXUVC.W801; 2nd existing building (rear of site) 1 hr. FRR (existing) for north wall face. Existing Warehouse main floor 445.92m2. Existing office 1600sq ft. (148.6m2). Total area of main floor = 8400 sq.ft. (780.36m2) including addition; upper floor office = 1600sq.ft. Total building floor area = 10000sq. ft. 929m2. unsprinklered. Physical File Scanned + attached Aug 19, 2008 db |
| Application Status: | COMPLETED |
| Permit Value: | $65,292.38 |
| Builder: | F & M INSTALLATIONS LTD |
| Issued Date: | April 13, 2007 |
| File Close Date: | July 04, 2007 |
Associated Properties
| Address | Zone | More |
|---|---|---|
| 2363 CIENAR DRIVE | I2 | Property Report |
Process Steps
| Task | Status |
|---|---|
|
FOOTING/FORMS
Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite. |
PASSED |
|
PERIMETER DRAIN
For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering. |
PASSED |
|
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
FAILED |
|
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PASSED |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
FAILED |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
CANCELLED |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PASSED |
|
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PASSED |
|
PLUMBING FINAL-OLD
All fixtures must be in place. |
PARTIAL |
|
PLUMBING FINAL-OLD
All fixtures must be in place. |
PASSED |
|
FINAL-OLD
Final approval as per requirements on plans. |
FAILED |
|
FINAL-OLD
Final approval as per requirements on plans. |
PASSED
2007-07-04 |
| Map |
|---|
View in Google Earth (KML)
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

View in Google Earth (KML)