BP111001 - 580 Stewart

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP111001 - 580 Stewart
Neighbourhood: Newcastle/Brechin    
Street Address: 580 Stewart
Type of Application: Commercial / Multi / Industrial
File Number: BP111001
Date Application Submitted: December 12, 2006
Application Description: RENEWAL DUE DUE TO FIRE X REFERENCE BP108691
Bldg code description;4 separate buildings by (3.2.1.2.).2hr FRR/FS btwn storage garage & residential units.30 dwelling units total
Basement storage garage,2 levels (3.2.1.2 (1) by Equivalency A separate bldg),non-combustible,sprinklered,fire alarm.
Bldg A,total area = 2050.67 m2,area of 21 dwelling units only = 1779.81m2 Bldg area 550m2, 3.2.2.45,combustible,4 storeys, residential ,sprinklered,fire alarm,combustible,1 hr FRR/FS floor assemblies & loadbearing supports,1 hr.FRR/FS public corridors,1hr FRR/FS/50STM for dwelling unit separation.
Bldg B,total area =701.85 m2,Building area 210m2,Part 9,5 townhouse units,combustible,3 storeys,sprinklered,1hr FRR/FS/50STM btwn units,access to parking garage by equivalency B (audible bell connected to fire alarm).
Bldg C, total area =561.48 m2, Building area 175m2, Part 9, 4 townhouse units, 3 storeys, sprinklered,1hr FRR/FS/50STM.

Physical File Scanned + attached Dec 19 2008 db
Application Status: COMPLETED
Permit Value: $4,000,000.00
Builder: TERRA PACIFIC BUILDERS LTD
Issued Date: March 01, 2007
File Close Date: May 08, 2008

Associated Properties

Address Zone More
39 CYPRESS STREET COR2 Property Report
37 CYPRESS STREET COR2 Property Report
35 CYPRESS STREET COR2 Property Report
33 CYPRESS STREET COR2 Property Report
31 CYPRESS STREET COR2 Property Report
29 CYPRESS STREET COR2 Property Report
27 CYPRESS STREET COR2 Property Report
25 CYPRESS STREET COR2 Property Report
23 CYPRESS STREET COR2 Property Report
205   580 STEWART AVENUE COR2 Property Report
206   580 STEWART AVENUE COR2 Property Report
207   580 STEWART AVENUE COR2 Property Report
201   580 STEWART AVENUE COR2 Property Report
202   580 STEWART AVENUE COR2 Property Report
303   580 STEWART AVENUE COR2 Property Report
304   580 STEWART AVENUE COR2 Property Report
305   580 STEWART AVENUE COR2 Property Report
306   580 STEWART AVENUE COR2 Property Report
307   580 STEWART AVENUE COR2 Property Report
302   580 STEWART AVENUE COR2 Property Report
401   580 STEWART AVENUE COR2 Property Report
402   580 STEWART AVENUE COR2 Property Report
580 STEWART AVENUE COR2 Property Report
103   580 STEWART AVENUE COR2 Property Report
104   580 STEWART AVENUE COR2 Property Report
105   580 STEWART AVENUE COR2 Property Report
106   580 STEWART AVENUE COR2 Property Report
101   580 STEWART AVENUE COR2 Property Report
102   580 STEWART AVENUE COR2 Property Report
203   580 STEWART AVENUE COR2 Property Report
204   580 STEWART AVENUE COR2 Property Report

Process Steps

Task Status
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PARTIAL
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

FAILED
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

CANCELLED
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PASSED
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PARTIAL
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PARTIAL
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

FAILED
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PARTIAL
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PARTIAL
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PARTIAL
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PARTIAL
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

CANCELLED
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

CANCELLED
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PARTIAL
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PARTIAL
MONITORING FIELD REVIEW

A building official may attend the site from time to time during the course of construction to ascertain that the field reviews are taking place and to monitor the field reviews undertaken by the registered professional.

PARTIAL
MONITORING FIELD REVIEW

A building official may attend the site from time to time during the course of construction to ascertain that the field reviews are taking place and to monitor the field reviews undertaken by the registered professional.

PARTIAL
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

PASSED
PLUMBING FINAL-OLD

All fixtures must be in place.

PARTIAL
PLUMBING FINAL-OLD

All fixtures must be in place.

PASSED
OCCUPANCY-OLD CANCELLED
OCCUPANCY-OLD PARTIAL
OCCUPANCY-OLD PASSED

2008-05-08

FINAL-OLD

Final approval as per requirements on plans.

FAILED
FINAL-OLD

Final approval as per requirements on plans.

FAILED
FINAL-OLD

Final approval as per requirements on plans.

CANCELLED
FINAL-OLD

Final approval as per requirements on plans.

FAILED
FINAL-OLD

Final approval as per requirements on plans.

PARTIAL
FINAL-OLD

Final approval as per requirements on plans.

FAILED
Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.